Related Experiment Video
Updated: Feb 13, 2026
![Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58491.jpg&w=3840&q=50)
Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
Diagnostic Accuracy of Biomarkers and Imaging for Bone Turnover in Renal Osteodystrophy
Syazrah Salam1,2,3, Orla Gallagher3, Fatma Gossiel2,3
1Sheffield Kidney Institute, Sheffield Teaching Hospitals National Health Service Foundation Trust, Sheffield, United Kingdom; and Syazrah.Salam@sth.nhs.uk.
Abstract:
Background Renal osteodystrophy is common in advanced CKD, but characterization of bone turnover status can only be achieved by histomorphometric analysis of bone biopsy specimens (gold standard test). We tested whether bone biomarkers and high-resolution peripheral computed tomography (HR-pQCT) parameters can predict bone turnover status determined by histomorphometry.Methods We obtained fasting blood samples from 69 patients with CKD stages 4-5, including patients on dialysis, and 68 controls for biomarker analysis (intact parathyroid hormone [iPTH], procollagen type 1 N-terminal propeptide [PINP], bone alkaline phosphatase [bALP], collagen type 1 crosslinked C-telopeptide [CTX], and tartrate-resistant acid phosphatase 5b [TRAP5b]) and scanned the distal radius and tibia of participants by HR-pQCT. We used histomorphometry to evaluate bone biopsy specimens from 43 patients with CKD.Results Levels of all biomarkers tested were significantly higher in CKD samples than control samples. For discriminating low bone turnover, bALP, intact PINP, and TRAP5b had an areas under the receiver operating characteristic curve (AUCs) of 0.82, 0.79, and 0.80, respectively, each significantly better than the iPTH AUC of 0.61. Furthermore, radius HR-pQCT total volumetric bone mineral density and cortical bone volume had AUCs of 0.81 and 0.80, respectively. For discriminating high bone turnover, iPTH had an AUC of 0.76, similar to that of all other biomarkers tested.Conclusions The biomarkers bALP, intact PINP, and TRAP5b and radius HR-pQCT parameters can discriminate low from nonlow bone turnover. Despite poor diagnostic accuracy for low bone turnover, iPTH can discriminate high bone turnover with accuracy similar to that of the other biomarkers, including CTX.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Turnover Number and Catalytic Efficiency
Chymotrypsin is a pancreatic enzyme that breaks down proteins during digestion....
Accuracy, limits, and approximation
Accuracy is defined as the closeness of the measured value to the true or actual value. In engineering mechanics, repeated measurements are taken during theoretical or experimental analyses to ensure that the result is precise and accurate.
The accuracy of any solution is based on the...

