Related Experiment Video
Updated: Feb 13, 2026

Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
Extra-small dual-lumen micro-balloon catheters can improve endovascular embolization: an experimental in vivo and in
Dominik F Vollherbst1,2, Ruth Otto1, Thuy D Do2
1Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany.
Background:
The embolization technique can have significant impact on the success of endovascular embolization.
Objective:
To evaluate the feasibility, embolization characteristics, and embolization extent with a newly developed extra-small micro-balloon catheter in an in vivo and in an in vitro embolization model in comparison with standard microcatheter embolizations.
Materials And Methods:
Twenty-eight embolization procedures were performed in the porcine rete mirabile (RM) and in an in vitro embolization model, using either an extra-small (distal outer diameter 1.6 F) dual-lumen micro-balloon catheter or a standard microcatheter. Precipitating hydrophobic injectable liquid (PHIL) was used as embolic agent. Procedure times, number of injections, required volume of embolic agent, and embolization extent (percentage of embolized RM in postinterventional X-ray scans or number of filled sections of the in vitro model) were assessed. Histopathological analyses were performed.
Results:
Total procedure time was significantly shorter (in vivo: 123 s vs 615 s (medians), P=0.001; in vitro: 180 s vs 496 s (medians), P=0.001), number of reflux events was significantly lower (in vivo: 0 vs 9 (medians), P=0.001; in vitro: 0 vs 3 (medians), P=0.001), and embolization extent was significantly higher (in vivo: 96.9% vs 65.6% (medians), P=0.011; in vitro: 26 vs 18 filled sections (medians); P=0.041) for the micro-balloon catheter groups. There was antegrade movement of the PHIL cast after balloon deflation in one in vitro embolization procedure and spontaneous balloon deflation with subsequent reflux in one in vivo embolization procedure.
Conclusion:
Extra-small dual-lumen micro-balloon catheters can improve endovascular embolization in comparison with standard microcatheter embolization.
Related Concept Videos
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Pulmonary Embolism I: Introduction
Equivalence: In Vitro and In Vivo Bioequivalence
Pulmonary Embolism III: Nursing Management
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...
Drug Product Performance: In Vitro–In Vivo Correlation