We report the case of a 44-year-old pregnant woman who was diagnosed with symptomatic severe mitral stenosis that did not respond to optimal medical therapy and balloon valvuloplasty. After a multidisciplinary team discussion on the timing and risks of interventions and postoperative optimization of peripartum anticoagulation, the patient underwent mechanical mitral valve replacement during the 2nd trimester of pregnancy. The outcome was excellent for the mother and the infant. This case emphasizes the importance of a multidisciplinary approach in managing unusual cases.
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...