Related Experiment Video
Updated: Feb 13, 2026

Live Imaging of Mouse Secondary Palate Fusion
Published on: July 27, 2017
Role of fusional convergence amplitude in postoperative phoria maintenance in children with intermittent exotropia
Akemi Wakayama1, Yukari Seki2, Rika Takahashi2
1Department of Ophthalmology, Kindai University Faculty of Medicine, 377-2 Ohno-Higashi, Osaka-Sayama City, Osaka, 589-8511, Japan. akemi-wakayama@med.kindai.ac.jp.
Purpose:
To examine the role of fusional convergence amplitude in postoperative phoria maintenance in childhood intermittent exotropia [X(T)].
Methods:
The medical records of 29 children aged 15 years or younger (mean age, 10.8 ± 2.4 years) and treated with monocular recession-resection for X(T) were reviewed retrospectively. The patients' fusional convergence amplitude (break point/total amplitudes), physiologic diplopia, and phoria maintenance (presence/absence of phoria maintenance and ability to maintain phoria) were assessed. The presence of phoria maintenance was confirmed by a cover test, and the ability to maintain phoria was quantified using the Bagolini red filter bar. Correlations of the amplitude size with the presence and ability of phoria maintenance were investigated.
Results:
A significant correlation was seen between fusional amplitude (break point/total) and ability to maintain phoria at near and at far (break point: P < .05 at near/P < .01 at far; total: P < .05 at near/far). Neither the break point amplitude nor the total amplitude significantly differed between the patients with phoria maintenance and those without it (break point: P = .71 at near, P = .29 at far; total: P = .98 at near, P = .85 at far). Phoria maintenance correlated with the suppression of physiologic diplopia during phoria (P < .01). The deviation angle did not significantly correlate with fusional amplitude either at near (P = .58) or at far (P = .27).
Conclusions:
In childhood X(T), fusional amplitude plays a role in enforcing the patient's ability to maintain phoria. However, sufficient fusional amplitude does not guarantee fully functioning fusion if suppression is present during phoria.
More Related Videos
05:15Author Spotlight: Accessible M&M-Based Mouse Model for Investigating Binge Eating Disorder - Insights into Eating Behaviors, Anxiety, and Neural Mechanisms
Published on: January 10, 2025
08:44Separation of Immune Cell Subpopulations in Peripheral Blood Samples from Children with Infectious Mononucleosis
Published on: September 7, 2022
Related Concept Videos
Convergent Evolution
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Region of Convergence
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Convergence of Fourier Series
The Gibbs phenomenon refers to the persistent oscillations and overshoots that occur near discontinuities...
Maintenance of the ES Cell State