Related Experiment Video
Updated: Feb 13, 2026

Measuring the Osmotic Water Permeability Coefficient Pf of Spherical Cells: Isolated Plant Protoplasts as an Example
Published on: October 8, 2014
Repeatability of n-octanol/water partition coefficient values between liquid chromatography measurement methods
Parichehr Saranjampour1, Kevin Armbrust2
1Department of Environmental Sciences, College of the Coast and Environment, Louisiana State University, Energy, Coast and Environment Building, Baton Rouge, LA, 70803, USA. psaranja@mtu.edu.
Abstract:
The n-octanol/water partition coefficient (KOW) is a physical/chemical property that is extensively used for regulatory and environmental risk and exposure assessments. The KOW value can estimate various chemical properties such as water solubility, bioavailability, and toxicity using quantitative structure-activity relationships which demands an accurate knowledge of this property. The present investigation aims to compare outcomes of three commonly cited methods of KOW measurement in the literature for six hydrophobic chemicals with insecticidal functions as well as highly volatile petroleum constituents. This measurement has been difficult to obtain for the selected pyrethroid insecticides, cypermethrin, and bifenthrin and is a novel measurement for the latter: polycyclic aromatic sulfur heterocycles, dibenzothiophene (DBT), and three of its alkyl derivatives except for DBT. The KOW values were obtained using two liquid chromatographic methods with isocratic and gradient programming, and the slow-stirring method following OECD 117 and 123 guidelines, respectively. The mean log KOW values of bifenthrin, cypermethrin, DBT, methyl-DBT, dimethyl-DBT, and diethyl-DBT were 8.4 ± 0.1, 6.0 ± 0.3, 4.8 ± 0.0, 5.4 ± 0.1, 6.0 ± 0.1, and 6.8 ± 0.0 using the HPLC method with gradient programing. The KOW values were significantly reproducible within a method, however, not between the methods. Results suggest assessing a chemical's property and environmental risk and exposure solely based on the KOW value should be practiced with caution.
Related Concept Videos
Extraction: Partition and Distribution Coefficients
For extracting a solute from an aqueous phase into an...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Biodiversity and Human Values