In a Heartbeat: An Assessment of Dynamic Dose Variation to Cardiac Structures Using Dual Source Computed Tomography
Houda Bahig1, Jacques de Guise2, Toni Vu1
1Department of Radiation Oncology, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada; Research Center, Centre Hospitalier de l'Université de Montréal, Montreal, Quebec, Canada.
Purpose:
To assess radiation dose variation to the left anterior descending artery (LAD), left main coronary artery (LMCA), left ventricle (LV), and whole heart (WH) during the cardiac cycle using dual source computed tomography (DSCT).
Methods And Materials:
The present prospective study included patients with left-side breast cancer planned to undergo tangential radiation therapy. An electrocardiogram-synchronized contrast-injected DSCT scan was obtained with the patient in the treatment position, in deep-inspiration breath-hold, using retrospective sequential acquisition. The WH, LV, LMCA, and proximal, middle, and distal LAD segments were contoured on each phase of the cardiac cycle. The maximum, minimum, and mean Hausdorff distance between each structure and the tangential fields was assessed in ventricular systole and diastole. Four-dimensional dose-volume histograms were used to compare the systolic and diastolic dosimetric data.
Results:
Ten patients were enrolled. The average maximum, minimum, and mean Hausdorff distance variation from systole to diastole was ≤4 mm for the LV and LMCA and ≤3 mm for the WH and LAD segments. WH maximum dose and volume receiving 5 Gy were decreased in systole compared with diastole (42.9 Gy versus 44.5 Gy, P = .03, and 21.7 cm3 versus 27.7 cm3, P = .01), but the mean dose remained similar throughout the cycle. The maximum and mean dose to the distal LAD was 21.2 Gy versus 26.6 Gy (P = .005) and 8.6 Gy versus 13.2 Gy (P = .006) in systole versus diastole, respectively. The maximum and mean dose to the middle LAD was 18.4 Gy versus 25.1 Gy (P = .005) and 8.5 Gy versus 10.2 Gy in systole versus diastole (P = .005). The maximum dose to the LV was lower in systole than in diastole (21.5 Gy vs 26.7 Gy; P = .005).
Conclusions:
In addition to deep-inspiration breath-hold, systolic irradiation is associated with a reduction in dose to the LAD, LV, and WH. In addition to its potential use in radiation planning for cardiac gating, DSCT imaging can be used to help define a planning organ at risk volume for clinically important cardiac substructures.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Structure of Cardiac Muscles
Compared to skeletal muscles, cardiac muscle cells are small and mostly have a single nucleus. Additionally, they are usually...
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation: Normal Distribution, Range, and Standard Deviation
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...