Related Experiment Video
Updated: Feb 13, 2026

09:35
Subcutaneous Trigeminal Nerve Field Stimulation for Refractory Facial Pain
Published on: May 10, 2017
19.6K
Pulsed Radiofrequency for Treating Trigeminal Neuralgia
Alaa Abd-Elsayed1, Laura Kreuger2, Susanne Seeger3
1Department of Anesthesiology, University of Wisconsin School of Medicine and Public Health, Madison, WI.
Ochsner Journal
|March 22, 2018
Summary
Pulsed radiofrequency (PRF) via the transcoronoid approach offers a safe and effective treatment for trigeminal neuralgia. This method shows promise for patients unresponsive to conventional therapies, with all cases reporting improvement and no complications.
Area of Science:
- Neurosurgery
- Pain Management
- Neurology
Background:
- Trigeminal neuralgia is a common yet challenging facial pain condition.
- Medications can be ineffective, and surgery carries risks of complications.
- Pulsed radiofrequency (PRF) presents a potential alternative treatment modality.
Purpose of the Study:
- To evaluate the efficacy and safety of PRF using the transcoronoid approach for trigeminal neuralgia.
- To assess pain reduction and treatment outcomes in patients refractory to standard care.
Main Methods:
- Retrospective analysis of 8 patient cases.
- Data collected from electronic medical records.
- Outcomes measured by pre- and post-procedure pain scores and improvement percentages.
Main Results:
- The study included patients with an average age of 56.4 years.
- All patients experienced pain improvement post-procedure.
- Three patients maintained ongoing improvement at follow-up; no complications were reported.
Conclusions:
- PRF via the transcoronoid approach demonstrates safety and effectiveness.
- This technique is a viable option for trigeminal neuralgia patients resistant to conservative management.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
1.8K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.8K
Pulse
2.2K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.2K
Pulse
4.2K
The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
4.2K
Pulse Oximetry
1.4K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.4K
Regulation of Pulse
2.3K
Pulse regulation involves physiological mechanisms that ensure adequate blood flow throughout the body. The heartbeat, regulated by the autonomic nervous system, is influenced by hormonal balance, physical activity, and emotional state.
2.3K
Pulse rhythm
1.4K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.4K

