Related Experiment Video
Updated: Feb 13, 2026

07:40
Production of Metal Nanoparticles by Pulsed Laser-ablation in Liquids: A Tool for Studying the Antibacterial Properties of Nanoparticles
Published on: June 2, 2017
15.8K
Pulsed Radiofrequency Ablation for Treating Sural Neuralgia
Alaa Abd-Elsayed1, Markus Jackson1, Elizabeth Plovanich2
1Department of Anesthesiology, University of Wisconsin School of Medicine and Public Health, Madison, WI.
Ochsner Journal
|March 22, 2018
Summary
Pulsed radiofrequency ablation offers effective pain relief for persistent sural neuralgia when conservative treatments fail. This minimally invasive procedure provided significant improvement in two challenging cases.
Area of Science:
- Pain Management
- Neurology
- Interventional Pain Procedures
Background:
- Sural neuralgia, characterized by persistent pain in the sural nerve distribution, is a rare yet debilitating condition.
- It often presents challenges in treatment, significantly limiting patients' quality of life.
- Conservative management strategies frequently prove insufficient for effective pain control.
Observation:
- Two distinct cases of refractory sural neuralgia are presented.
- One patient developed neuralgia post-foot surgery; the other experienced it after falls.
- Both patients had failed multiple conservative treatment modalities.
Findings:
- Diagnostic nerve blocks were performed in both cases.
- Pulsed radiofrequency ablation (pRF) was administered to both patients.
- Both patients reported an 80% improvement in pain following pRF treatment.
Implications:
- Pulsed radiofrequency ablation demonstrates potential as a safe and effective therapeutic option for recalcitrant sural neuralgia.
- Further research is warranted to establish the definitive efficacy and safety profile of pRF for this condition.
- This technique may offer a viable alternative for patients unresponsive to conventional therapies.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
1.8K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.8K
Pulse
2.2K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.2K
Pulse
4.2K
The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
4.2K
Pulse Oximetry
1.4K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.4K
Regulation of Pulse
2.3K
Pulse regulation involves physiological mechanisms that ensure adequate blood flow throughout the body. The heartbeat, regulated by the autonomic nervous system, is influenced by hormonal balance, physical activity, and emotional state.
2.3K
Pulse rhythm
1.4K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.4K

