Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty
Published on: September 17, 2014
Cumulative Endothelial Cell Loss in Descemet Membrane Endothelial Keratoplasty Grafts From Preparation Through
Kenneth Downes1, Khoa D Tran2, Christopher G Stoeger2
1Division of Cornea and Refractive Surgery, Casey Eye Institute, Department of Ophthalmology, Oregon Health & Science University, Portland, OR.
Purpose:
Evaluation of cumulative Descemet membrane endothelial keratoplasty endothelial cell loss (ECL) from preparation through injection using 2 different glass injectors.
Methods:
Eighteen Descemet membrane endothelial keratoplasty grafts with "S" stamps were prepared by eye bank technicians. Nine grafts were assigned to injection with a modified glass Jones tube injector with a 2.4-mm opening and 9 were assigned to injection with the DORC glass pipette injector (<1.5-mm opening). The grafts were prepared and loaded into the injectors using the standard surgical technique, ejected onto a bed of viscoelastic on a glass slide, and unscrolled using viscoelastic. The grafts were stained with the vital dye Calcein-AM, then digitally imaged and analyzed using FIJI. The percentage of ECL was calculated by measuring the area of nonfluorescent pixels and dividing it by the total graft area pixels. A statistical comparison was performed using a 2-tailed unpaired t test.
Results:
Grafts injected using the DORC injector versus Jones tube injector had ECL of 29.2% ± 8.5% [95% confidence interval (CI)] versus 23.0% ± 5.1% (95% CI), respectively. This difference was not statistically significant (P = 0.17); however, the patterns of ECL on the grafts was different between injectors. Peripheral ECL caused by trephination and surgeon grasp sites accounted for 7.5% ± 1.2% (95% CI).
Conclusions:
There was no statistical difference in ECL between the 2 injectors. There were characteristic differences in patterns of ECL seen between injectors, which may be clinically relevant and indicate the types of stress that grafts are exposed to during passage through various injectors.
Related Concept Videos
Porin Insertion in the Outer Mitochondrial Membrane
Three models describe the assembly of porins by the SAM complex and their insertion into the outer membrane. Model 1 suggests that porins are assembled outside the SAM channel as the...
Cumulative Frequency Distribution
The Looking Glass Self
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...