Palatal volume and area assessment on digital casts generated from cone-beam computed tomography scans
Objectives:
The objective of this study was to develop a reproducible method to measure the change of palatal volume and area through superimposition using maxillary expansion digital cast models.
Materials And Methods:
A total of 10 pre- and 10 postexpansion dental cast models were scanned by the same cone-beam computed tomography machine. Superimposition was performed using a fully automated surface-best fit of the palatal surfaces on the digital cast models. A gingival plane, identified only once on superimposed casts, and a distal plane with the lateral closing border and the palatal surface were used to localize this selection of air. Area and volume were calculated for pre- and postexpansion records. Pre- and postexpansion palatal volume and area were measured by the main investigator and three different observers for inter- and intra-observer reproducibility assessment.
Results:
The level of intra- and inter-observer agreement was very strong (intraclass correlation coefficients ≥ 0.953; P value < .0001) for all measurements.
Conclusions:
Palatal volume and area measurements based on the proposed superimposition are reproducible and can be used reliably.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Leaky Scanning
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...