Related Experiment Video
Updated: Feb 13, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Parameters influencing the quality of colonoscopy in Belgium : a critical evaluation
E Macken1, S Van Dongen2, S Francque1
1Antwerp University Hospital, 2650 Edegem, Antwerp, Belgium.
Background And Study Aims:
In relation to recent implementation of colorectal cancer screening programs at the regional level, quality assessment of colonoscopy gains more interest in Belgium. In order to evaluate quality indicators of colonoscopies in Belgium, we retrospectively analysed data about colonoscopies performed between 2002-2010.
Patients And Methods:
Coded data concerning number of medical procedures and polypectomy were provided by the Intermutualistic Agency (IMA). This database was used to calculate different quality indicators such as polyp detection rate (PDR), use of sedation, amount of procedures and time interval according to physician and center type.
Results:
Considerable differences in polyp detection rate (PDR) exist between different physicians and centers. Mean PDR significantly correlated with the number of colonoscopies performed each year. A minimum of 106 colonoscopies per year was identified to maintain competence. Recuperation rate for polyps was low, and time intervals between colonoscopies were generally too short in comparison to European and international guidelines.
Conclusions:
In absence of a central colonoscopy registry in Belgium, our results were based on reimbursement data. Other quality parameters, although accuracy is questionable (eg. bowel cleansing and withdrawal time) are not systematically registered. Despite these difficulties, we were able to demonstrate that a minimum amount of 106 colonoscopies per year is necessary to maintain competence. The results from this large database can be used as a foundation to work out a quality colonoscopy bundle.
Related Concept Videos
Factors Influencing Drug Absorption: Pharmaceutical Parameters
Factors Influencing Drug Absorption: Anatomical Parameters
Factors Influencing Drug Absorption: Physicochemical Parameters
Enhanced drug absorption can be achieved by reducing particle sizes and increasing surface areas, thereby facilitating...
Endoscopic Procedures II: Colonoscopy
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...
Critical Values

