Ultrasonic Mist Generation Assist Argon-Nitrogen Mix Gas Effect on Radioactive Strontium Quantification by Online
Makoto Furukawa1,2,3, Makoto Matsueda1, Yoshitaka Takagai1,4
1Faculty of Symbiotic Systems Science, Cluster of Science and Technology, Fukushima University.
Abstract:
The Ar-N2 mix gas effect can easily improve the sensitivity of ICPMS; however, this effect discriminates against Sr. In this study, it was found that Ar-N2 mixed gases introduced into nebulizing gas enhanced the sensitivity of online solid-phase extraction (SPE) with inductively coupled plasma mass spectrometry (ICPMS) for radioactive strontium quantification. An ultrasonic nebulizer (USN) improved the Ar-N2 mixture gases effect of Sr and the mix gases (with USN) enhanced 3.7-times the signal intensity of Sr in normal pure Ar gas (with USN) in an online SPE-ICPMS. By adapting the gas-loading means from a nebulizing gas unit via USN, no careful tuning was necessary for the plasma turning. With this signal enhancement, a 0.06 pg/L detection limit (0.3 Bq/L) was achieved for radioactive strontium (90Sr) in online SPE-ICPMS within 30 min. In addition, environmental paddle water in the Fukushima Nuclear Power Plant was measured and the valued correspond to that obtained by radiometry.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductance: Single-Phase And Three-Phase Line
Single-Phase Two-Wire Line:
A single-phase line consists of two solid cylindrical conductors, denoted as x and y. Each conductor carries phasor currents ix and iy, respectively. Given that the sum of these currents is...