Insights
Left atrial appendage closure (LAAC) using the Watchman device is a safe and effective stroke prevention method for patients with non-valvular atrial fibrillation (NVAF), including those with chronic kidney disease (CKD). This real-world study confirms LAAC
Area of Science:
- Cardiology
- Nephrology
- Medical Devices
Background:
- Chronic kidney disease (CKD) is highly prevalent in patients with atrial fibrillation (AF).
- Left atrial appendage closure (LAAC) is an alternative to oral anticoagulation for preventing thromboembolic events in non-valvular AF (NVAF).
- Long-term safety and efficacy of LAAC in NVAF patients with CKD require further investigation.
Purpose of the Study:
- To evaluate the safety and efficacy of LAAC using the Watchman (WM) device in NVAF patients with and without CKD.
- To compare outcomes between NVAF patients with CKD and those without CKD undergoing LAAC.
Main Methods:
- A real-world analysis of 300 NVAF patients (151 with CKD, 149 without CKD) who underwent LAAC with the WM device.
- Comparison of baseline characteristics, device implant success rates, and periprocedural complications.
- Follow-up for an average of 637 days with transesophageal echocardiography (TEE) to assess device-related thrombi, ischemic strokes, and major bleeding.
Main Results:
- Patients with CKD were older and had higher CHA2DS2-VASc and HAS-BLED scores, but implant success and periprocedural complication rates were similar between groups.
- No significant differences in device-related thrombi, ischemic strokes, or major bleeding were observed between CKD and non-CKD groups.
- Kaplan-Meier analysis showed a significant reduction in thromboembolic events and bleeding rates in both groups post-LAAC, with greater reduction in CKD patients.
Conclusions:
- LAAC with the Watchman device is a safe and effective strategy for stroke prevention in NVAF patients, irrespective of their CKD status.
- The study provides real-world evidence supporting the use of LAAC in NVAF patients with comorbid CKD.
Abstract:
The prevalence of chronic kidney disease (CKD) is high in patients with atrial fibrillation (AF). Left atrial appendage closure (LAAC) has been recognized as an efficient alternative to oral anticoagulation for the prevention of thromboembolic events in patients with non-valvular AF (NVAF); however, the long-term safety and efficacy of LAAC in patients with CKD remain unclear. This study was designed to provide data regarding the safety and efficacy of LAAC in NVAF patients with CKD. A real-world analysis of the safety and efficacy of LAAC was performed on a cohort of 300 NVAF patients with or without CKD who underwent LAAC using the Watchman (WM) device at our center. The patients with CKD (n = 151) were significantly older (77.0 ± 7.2 vs. 73.2 ± 7.8 years, respectively, P < 0.0001) and had a higher CHA2DS2-VASc score (4.3 ± 1.5 vs. 3.4 ± 1.4, respectively, P < 0.0001) and HAS-BLED score (4.0 ± 1.0 vs. 3.0 ± 1.0, respectively, P < 0.0001) than the patients without CKD (n = 149). However, there were no differences between groups with respect to the device implant success rate (98.7 vs. 97.3%, respectively, P = 0.446) or severe periprocedural complications within 7 days. The patients were followed up for 637 ± 398 days, and all patients received repeat transesophageal echocardiography (TEE). Thirteen (4.3%) device-related thrombi, 3 (1.0%) ischemic strokes, and 19 (6.3%) non-procedural major bleeding cases were documented, and there were no differences in these complications between groups. The observed rate of all thromboembolic events by Kaplan-Meier analysis decreased by 68.8% (CKD) and 48.6% (non-CKD); moreover, the observed annual rate of bleeding was reduced by 57.5% (CKD) and 11.4% (non-CKD). Our results indicate that LAAC with the WM device is safe and effective in preventing stroke in NVAF patients with and without CKD.
Related Concept Videos
Chronic Kidney Disease I: Introduction
Chronic Kidney Disease II: Clinical Manifestations
Chronic Kidney Disease III: Interprofessional Care
Chronic Kidney Disease IV: Nursing Management
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Chronic Obstructive Pulmonary Disease-I: Introduction