Related Experiment Video
Updated: Feb 12, 2026

Online Transcranial Magnetic Stimulation Protocol for Measuring Cortical Physiology Associated with Response Inhibition
Published on: February 8, 2018
Short Interval Intracortical Inhibition Responses to Low-Frequency Repetitive Transcranial Magnetic Stimulation Under
Mo Chen1,2, Maíra C Lixandrão1,3, Cecília N Prudente1
1Division of Physical Therapy, Department of Rehabilitation Medicine, School of Medicine, University of Minnesota, Minneapolis, MN, USA.
Background:
The extent to which short interval intracortical inhibition (SICI) responds to low-frequency repetitive transcranial magnetic stimulation (rTMS) remains inconclusive with reports of increased, decreased and unchanged response following modulation. The aim of this study was to systematically investigate if the variability of SICI following rTMS is explained by the interstimulus interval (ISI) and/or the conditioning stimulus intensity (CSI).
Methods:
Two experiments with pretesting/posttesting and an rTMS session (1 Hz, 90% RMT, 900 pulses) were done. Experiment I (N = 15): SICI with multiple ISIs (1.0-4.0 msec, 0.2 msec increment). Experiment II (N = 15): SICI with CSIs (50-95% of RMT, 5% increment). In both experiments, the cortical silent period (cSP) was also collected.
Results:
After low-frequency rTMS, no significant change (p > 0.10) in SICI at any specific ISI or CSI was observed, nor did the optimal ISI or CSI change. However, a significant decrease was observed in SICI responses when assessed under the range of ISIs (p = 0.0001), but not CSIs. cSP inhibition increased significantly (p < 0.0015) for both experiments.
Conclusions:
The optimal ISI or CSI did not shift or reveal SICI changes after inhibitory rTMS. However, when the whole curve of SICI responses were evaluated from a wide range of ISIs, a decrease in inhibition was found. The contrast between the results of individual ISI tests and the wide range of ISI assessment may be due to higher intersubject variability of SICI and/or sample size, rendering traditional SICI testing methods ineffective for measuring changes in inhibition. Further, it is possible that rTMS modulates GABAA and GABAB mediated inhibitory processes differently, which would explain the conflicting results for SICI and cSP.
Related Concept Videos
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
Confidence Intervals
A...
Improper Integrals: Infinite Intervals
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Interpretation of Confidence Intervals
Confidence intervals have confidence coefficients that are crucial for their interpretation. The most common confidence coefficients are 0.90, 0.95, and 0.99, which can be written as percentages–90%, 95%, and 99%, respectively.
Suppose a person calculates a confidence interval with a confidence coefficient of 0.95. In that case, they can...
Uncertainty: Confidence Intervals

