Variations in Practice Patterns and Consistency With Published Guidelines for Balloon Aortic and Pulmonary
Andrew C Glatz1, Kevin F Kennedy2, Jonathan J Rome3
1Division of Cardiology, Children's Hospital of Philadelphia, Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania; Center for Pediatric Clinical Effectiveness, Children's Hospital of Philadelphia, Department of Pediatrics, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania.
Objectives:
The authors sought to study variation in the practice of balloon aortic (BAV) and pulmonary valvuloplasty (BPV).
Background:
The IMPACT (IMProving Adult and Congenital Treatment) registry provides an opportunity to study practice variation in transcatheter interventions for congenital heart disease.
Methods:
The authors studied BAV and BPV in the IMPACT registry from January 1, 2011, to September 30, 2015, using hierarchical multivariable models to measure hospital-level variation in: 1) the distribution of indications for intervention; and 2) in cases with "high resting gradient" as the indication, consistency with published guidelines.
Results:
A total of 1,071 BAV cases at 60 hospitals and 2,207 BPV cases at 75 hospitals were included. The indication for BAV was high resting gradient in 82%, abnormal stress test or electrocardiogram (2%), left ventricular dysfunction (11%), and symptoms (5%). Indications for BPV were high resting gradient in 82%, right-left shunt (6%), right ventricular dysfunction (7%), and symptoms (5%). No association between hospital characteristics and distribution of indications was demonstrated. Among interventions performed for "high resting gradient," there was significant adjusted hospital-level variation in the rates of cases performed consistently with guidelines. For BAV, significant differences were seen across census regions, with hospitals in the East and South more likely to practice consistently than those in the Midwest and West (p = 0.005). For BPV, no association was found between hospital factors and rates of consistent practice, but there was significant interhospital variation (median rate ratio: 1.4; 95% confidence interval: 1.2 to 1.6; p < 0.001).
Conclusions:
There is measurable hospital-level variation in the practice of BAV and BPV. Further research is necessary to determine whether this affects outcomes or resource use.
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation: Normal Distribution, Range, and Standard Deviation
Analysis of Population Pharmacokinetic Data
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...