Development and validation of a hydrophilic interaction liquid chromatography method for the quantitation of
George Machairas1, Irene Panderi1, Ariadni Geballa-Koukoula1
1National and Kapodistrian University of Athens, Faculty of Pharmacy, Laboratory of Pharmaceutical Analysis, Panepistimiopolis, Athens GR 157 71, Greece.
Abstract:
A hydrophilic interaction liquid chromatography method with diode array detection (HILIC-DAD) was developed and validated for the simultaneous determination of impurities in extended-release fixed-dose combination tablets containing rosuvastatin and metformin in a ratio 1:100. The analytes were separated by hydrophilic interaction liquid chromatography using an XBridge®-HILIC analytical column under isocratic elution. The mobile phase was composed of ammonium formate at 150 mM containing 0.05% diethylamine (pH 8.5)/acetonitrile, 4/96 (v/v) and pumped at a flow rate of 0.5 mL min-1. Method validation was performed according to ICH guidelines. The calibration curves for rosuvastatin, metformin and their seven impurities showed good linearity (r > 0.994) within the calibration ranges tested. The intra- and inter-day R.S.D. values were less than 4.5%, while the relative percentage error Er was less than 2.7% for all compounds. Accelerated stability studies performed under various stress conditions including hydrolysis, oxidation and heat proved the selectivity of the procedure. A run time of less than 25 min for each sample made it possible to analyze a large number of samples per day. The method is the first reported application of HILIC for the analysis of impurities in fixed-dose combination tablets containing rosuvastatin and metformin and it can be used for the quality control of these drugs.
More Related Videos
09:57Development and Validation of a Quantitative PCR Method for Equid Herpesvirus-2 Diagnostics in Respiratory Fluids
Published on: March 17, 2016
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Related Concept Videos
Dosage Regimen: Fixed Dose
Fixed-dose regimens can be used for various routes of administration, including intravenous (IV) injections and oral medications. For IV administration, a predetermined amount of the drug is...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Dose Size and Dosing Frequency: Determination Methods
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
