Electrochemical detection of c-reactive protein based on anthraquinone-labeled antibody using a screen-printed
Sakda Jampasa1, Weena Siangproh2, Rawiwan Laocharoensuk3
1Program in Petrochemistry, Faculty of Science, Chulalongkorn University, Pathumwan, Bangkok 10330, Thailand.
Abstract:
In this present work, a novel electrochemical immunosensor employing a screen-printed graphene electrode (SPGE) for a simple and highly sensitive determination of C-reactive protein (CRP) in a sandwich-type format was proposed. The sensor comprised of two CRP-specific antibodies: an unlabeled capture primary antibody (Anti-1°Ab) and an electrochemically detectable anthraquinone-labeled signaling secondary (AQ-2°Ab) antibody. The Anti-1°Ab was first covalently anchored onto an L-cysteine/gold-modified disposable SPGE (L-Cys/Au/SPGE) to create the anti-CRP surface. After binding of the CRP and the AQ-2°Ab, the electrochemical signal response was measured using differential pulse voltammetry (DPV). In the presence of CRP, the sensor exhibited a significant increase in the AQ current at AQ-2°Ab compared to the negative control. The CRP concentration was detected in the range of 0.01-150 µg/mL, and the limit of detection (LOD) (S/N = 3) and limit of quantitation (LOQ) (10 SD/Slope) were 1.5 ng/mL and 10 ng/mL, respectively. This sensor exhibited very high sensitivity in determining CRP and was successfully applied to detect CRP in certified human serum with satisfactory results. The developed sensor is suitable as an alternative method for determination of CRP and the same principle may be further applied to determine other clinically important target molecules.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
Standard Electrode Potentials
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Cross-reactivity
Reactivity of Enols