Comparing capsular bag performance of a hydrophilic and a hydrophobic intraocular lens: A randomised two-centre study
John Koshy1, Nino Hirnschall1,2, Ashok Kumar V Vyas3
11 Moorfields Eye Hospital NHS Foundation Trust, London, UK.
Purpose::
To evaluate the capsular bag performance and posterior capsule opacification development of two intraocular lenses differing in material and design.
Methods::
This study included patients who were scheduled for cataract surgery and compared a hydrophilic intraocular lens (Super flex® intraocular lens; Rayner Surgical, Worthing, UK) with a hydrophobic intraocular lens (AcrySof® SA60AT; Alcon, Fort Worth, TX, USA). Follow-ups were performed 1 month and 2 years after cataract surgery, including a slit lamp examination and retroillumination images.
Results::
In total, 80 eyes of 80 patients were recruited. At the 1-month follow-up, 6 of 39 cases had a gap between the posterior lens capsule and intraocular lens (1 case in the hydrophilic intraocular lens group and 5 cases in the hydrophobic intraocular lens group; p = 0.348). Objective and subjective posterior capsule opacification scoring showed no statistically significant difference between both groups (p = 0.123).
Conclusion::
Both intraocular lens showed a good capsular bag performance and a relatively low posterior capsule opacification development within the first 2 years after surgery.
Related Concept Videos
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Comparative Excretory Systems
Comparing Experimental Results: Student's t-Test
Comparing the Survival Analysis of Two or More Groups
Comparing Mitochondrial, Chloroplast, and Prokaryotic Genomes
Pathophysiology of Cardiac Performance