Related Experiment Video
Updated: Feb 12, 2026

Author Spotlight: Advancements and Challenges in Surgical Treatments for Postamputation Pain
Published on: March 8, 2024
Marginal bone loss at implants with different surface characteristics - A 20-year follow-up of a randomized
Mauro Donati1, Annika Ekestubbe2, Jan Lindhe1
1Department of Periodontology, Institute of Odontology, The Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden.
Objective:
This report is a 20-year follow-up of a randomized controlled clinical trial evaluating the potential long-term effect of a modified implant surface on the preservation of the peri-implant marginal bone level.
Material & Methods:
In each of 51 patients and for each fixed partial denture (FPD), by randomization at least one implant installed had a non-modified turned surface and one a modified and roughened surface (TiOblast® ). Clinical and radiological examinations were performed at various follow-up intervals. Primary outcome variables were peri-implant marginal bone level change from time of loading and proportion of implants with no bone loss at 20 years. Multilevel analysis followed by nonparametric and Pearson's Chi-Square tests were applied for statistical analysis.
Results:
At the 20-year follow-up, 25 patients carrying 64 implants were available for evaluation. Turned and TiOblast implants presented with a mean bone level change from the time of FDP delivery amounting to -0.41 mm (95% CI -0.84/0.02) and -0.83 mm (95% CI -1.38/-0.28) respectively (inter-group comparison p > .05). 47% of the Turned and 34% TiOblast implants (p > .05) showed no bone loss. All but one of these implants were free of bacterial plaque and inflammation as well as presented with probing pocket depths ≤5 mm at both the 5- and 20-year follow-up examinations.
Conclusion:
It is suggested that a moderate increase of implant surface roughness has no beneficial effect on long-term preservation of the peri-implant marginal bone level.
More Related Videos
03:53Author Spotlight: Regenerative Peripheral Nerve Interface (RPNI) Surgery in Postamputation Pain Management
Published on: March 15, 2024
08:53Randomized, Triple-Blind, and Parallel-Controlled Trial of Transcranial Direct Current Stimulation for Cognitive Rehabilitation after Stroke
Published on: June 6, 2025
Related Concept Videos
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials
Characteristics of Life
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Trial and Error and Algorithm