ALEX index enables detection of alien macroalgae invasions across habitats within a marine protected area
L Piazzi1, P Gennaro2, F Atzori3
1Dipartimento di Scienze della Natura e del Territorio, Università di Sassari, Via Piandanna 4, 07100 Sassari, Italy.
Abstract:
A modified version of the ALien Biotic IndEX (ALEX) has been recently proposed to evaluate biological invasions in macroalgal assemblages. ALEX was applied in a Marine Protected Area where a recreational-fishing port is present testing the following hypotheses: ALEX increases with the distance from the port, it changes between the two directions off the port and it changes among three different habitats: Cystoseira beds, algal turf and dead matte of the seagrass Posidonia oceanica. A total of 78 native macroalgal taxa and 4 introduced species were found, the Chlorophyta Caulerpa cylindracea and the Rhodophyta Apoglossum gregarium, Acrothamnion preissii and Womersleyella setacea. All study sites were in high quality status highlighting that the assemblages investigated were at an early stage of NIS invasion. However, ALEX detected different values among conditions and habitats within the MPA, suggesting a local dynamics of NIS spread and different resistance to invasion of the investigated habitats.
More Related Videos
13:38Laser-Induced Fluorescence Emission L.I.F.E. as Novel Non-Invasive Tool for In-Situ Measurements of Biomarkers in Cryospheric Habitats
Published on: October 26, 2019
07:43Methods for Image-based Surveys of Benthic Macroinvertebrates and Their Habitat Exemplified by the Drop Camera Survey for the Atlantic Sea Scallop
Published on: July 2, 2018
Related Concept Videos
Habitat Fragmentation
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...