Related Experiment Video
Updated: Feb 12, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
High Efficiency Particulate Air Filters Do Not Affect Acute Infection Rates During Primary Total Joint Arthroplasty
Gannon L Curtis1, Mhamad Faour1, Jaiben George1
1Department of Orthopaedic Surgery, Cleveland Clinic, Cleveland, OH.
Background:
Studies have suggested that forced-air warmers (FAWs) increase contamination of the surgical site. In response, FAWs with high efficiency particulate air filters (FAW-HEPA) were introduced. This study compared infection rates following primary total joint arthroplasty (TJA) using FAW and FAW-HEPA.
Methods:
Primary TJA patients at a single healthcare system were retrospectively reviewed. A total of 5405 THA (n = 2419) and TKA (n = 2986) consecutive cases in 2013 and 2015 were identified. Patients in 2013 (n = 2792) had procedures using FAW, while FAW-HEPA was used in 2015 (n = 2613). The primary outcome was overall infection rate within 90-days. Sub-categorization of infections as periprosthetic joint infection (PJI) or surgical site infection (SSI) was also conducted. PJI was defined as reoperation with arthrotomy or meeting Musculoskeletal Infection Society (MSIS) criteria. SSI was defined as wound complications requiring antibiotics or irrigation/debridement.
Results:
The FAW and FAW-HEPA groups had similar rates of overall infection (1.65% [n = 46] vs 1.61% [n = 42], P > .99), SSI (1.18% [n = 33] vs 0.84% [n = 22], P = .27), and PJI (0.47% [n = 13] vs 0.77% [n = 20], P = .22). Regression models did not show FAW to be an independent risk factor for increased overall infection (odds ratio [OR] 1.00, 95% confidence interval [CI] 0.65-1.57, P = .97), SSI (OR 1.47, 95% CI 0.83-2.58, P = .18), or PJI (OR 0.53, 95% CI 0.25-1.13, P = .09).
Conclusion:
FAW were not correlated with a higher risk of overall infection, SSI, or PJI during TJA when compared to FAW-HEPA devices.
Related Concept Videos
Air-entraining Agents
Effects of Air-entrainment in Concrete
Measurement of Air Content in Concrete
The pressure method,...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Role of Affect in Interpersonal Attraction