Observer variability of reference tissue selection for relativecerebral blood volume measurements in glioma patients
Marcel T H Oei1, Frederick J A Meijer2, Jan-Jurre Mordang2
1Department of Radiology and Nuclear Medicine, Radboudumc, Geert Grooteplein 10, P.O. Box 9101, 6500 HB, Nijmegen, The Netherlands. mthoei@gmail.com.
Objectives:
To assess observer variability of different reference tissues used for relative CBV (rCBV) measurements in DSC-MRI of glioma patients.
Methods:
In this retrospective study, three observers measured rCBV in DSC-MR images of 44 glioma patients on two occasions. rCBV is calculated by the CBV in the tumour hotspot/the CBV of a reference tissue at the contralateral side for normalization. One observer annotated the tumour hotspot that was kept constant for all measurements. All observers annotated eight reference tissues of normal white and grey matter. Observer variability was evaluated using the intraclass correlation coefficient (ICC), coefficient of variation (CV) and Bland-Altman analyses.
Results:
For intra-observer, the ICC ranged from 0.50-0.97 (fair-excellent) for all reference tissues. The CV ranged from 5.1-22.1 % for all reference tissues and observers. For inter-observer, the ICC for all pairwise observer combinations ranged from 0.44-0.92 (poor-excellent). The CV ranged from 8.1-31.1 %. Centrum semiovale was the only reference tissue that showed excellent intra- and inter-observer agreement (ICC>0.85) and lowest CVs (<12.5 %). Bland-Altman analyses showed that mean differences for centrum semiovale were close to zero.
Conclusion:
Selecting contralateral centrum semiovale as reference tissue for rCBV provides the lowest observer variability.
Key Points:
• Reference tissue selection for rCBV measurements adds variability to rCBV measurements. • rCBV measurements vary depending on the choice of reference tissue. • Observer variability of reference tissue selection varies between poor and excellent. • Centrum semiovale as reference tissue for rCBV provides the lowest observer variability.
Related Concept Videos
Measurement of Blood Pressure
Inertial Frames of Reference
Non-inertial Frames of Reference
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...