Related Experiment Video For Carcinogenic risk
Updated: Feb 12, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Source apportionment and carcinogenic risk assessment of passive air sampler-derived PAHs and PCBs in a heavily
Banu Cetin1, Sema Yurdakul2, Elif Gungormus3
1Environmental Engineering Department, Gebze Technical University (GTU), 41400 Gebze, Kocaeli, Turkey.
Abstract:
Cancer has become the primary reason of deaths in Dilovasi probably due to its location with unique topography under the influence of heavy industrialization and traffic. In this study, possible sources and carcinogenic health risks of PAHs and PCBs were investigated in Dilovasi region by Positive Matrix Factorization (PMF) and the USEPA approach, respectively. PAHs and PCBs were measured monthly for a whole year at 23 sampling sites using PUF disk passive samplers. Average ambient air concentrations were found as 285±431ng/m3 and 4152±6072pg/m3, for Σ15PAH and Σ41PCB, respectively. PAH concentrations increased with decreasing temperature especially at urban sites, indicating the impact of residential heating in addition to industrial activities and traffic. On the other hand, PCB concentrations mostly increased with temperature probably due to enhanced volatilization from their sources. Possible sources of PAHs were found as emissions of diesel and gasoline vehicles, biomass and coal combustion, iron and steel industry, and unburned petroleum/petroleum products, whereas iron-steel production, coal and biomass burning, technical PCB mixtures, and industrial emissions were identified for PCBs. The mean carcinogenic risk associated with inhalation exposure to PAHs and PCBs were estimated to be >10-6 and >10-5, respectively, at all sampling points, while the 95th percentile was >10-5 at 15 of 23 and >10-4 at 8 of 23 sampling locations, respectively. Probabilistic assessment showed, especially for PCBs, that a majority of Dilovasi population face significant health risks. The higher risks due to PCBs further indicated that PCBs and possibly other pollutants originating from the same sources such as PBDEs and PCNs may be an important issue for the region.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024
Related Concept Videos
Mutagenicity and Carcinogenicity
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Design Example: Analyzing Capacity Contours for Flood Risk Assessment
Relative Risk
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Microorganisms in Agriculture and Food industry