Related Experiment Video
Updated: Feb 12, 2026

Author Spotlight: Exploring the Impact of Reduced Resistance Exercise Volume on Metabolic Health
Published on: December 1, 2023
The Effectiveness of Mini-C-Arm Fluoroscopy for the Closed Reduction of Distal Radius Fractures in Adults: A
Steven K Dailey1, Ashley R Miller1, Rafael Kakazu1
1Department of Orthopaedic Surgery, University of Cincinnati, Cincinnati, OH.
Purpose:
Most distal radius (DR) fractures are initially managed with closed reduction and orthosis application. Mini-C-arm fluoroscopy provides assessment of reduction quality in real time. Our null hypothesis was that there would be no difference in the reduction quality of DR fractures in the emergency department when using mini-C-arm fluoroscopy during reduction compared with standard reduction techniques (evaluating reduction quality with orthogonal radiographs taken in an orthosis).
Methods:
Sixty-three consecutive patients with closed DR fractures requiring reduction between April 2015 and April 2017 were prospectively randomized to standard versus fluoroscopically aided reductions. Reductions were performed by orthopedic surgery residents. The primary outcome measurement was reduction quality (radial height, radial inclination, ulnar variance, and volar tilt) as measured on postreduction radiographs.
Results:
Standard reductions were performed in 34 patients and fluoroscopically aided reductions in 29 patients. The 2 groups were similar in regards to all potential confounders that were analyzed. No differences in postreduction radial height, radial inclination, ulnar variance, or volar tilt were noted. Overall reduction attempts and subjective difficulty of fracture reduction were increased when using fluoroscopy. The rate of initial operative management did not differ between groups.
Conclusions:
The use of mini-C-arm fluoroscopy during the initial closed reduction of adult DR fractures results in equivalent postreduction radiographic parameters when compared with conventional reduction techniques. Additional research regarding time spent in the emergency department and overall cost could elucidate potential benefits of fluoroscopically aided DR fracture reduction.
Type Of Study/Level Of Evidence:
Therapeutic I.
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Radius of Gyration of an Area
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Schwarzschild Radius and Event Horizon
The minimum speed required to launch a projectile from the surface of an object to which it is gravitationally bound so that it eventually escapes the object’s gravitational field is called the escape velocity. The escape velocity is independent of the mass of the object. Merging the idea of escape...
Degree of Curvature and Radius of Curvature
Muscles that Move the Arm
The pectoralis major has two origins. Its clavicular head originates on the medial half of the clavicle. In contrast, the sternocostal head originates on the costal cartilages of ribs 1-6, the sternum, and the aponeurosis of the external oblique of the...

