Related Experiment Video
Updated: Feb 12, 2026

A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Thrombectomy using the EmboTrap device: core laboratory-assessed results in 201 consecutive patients in a real-world
Patrick A Brouwer1,2, Leonard L L Yeo1,2,3, Ake Holmberg1,2
1Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
Background:
We studied patients treated with the EmboTrap revascularization device in a prospective registry which is core laboratory evaluated by physicians from external centers. The goal was to determine how the EmboTrap would perform under the everyday conditions of a high-volume stroke center.
Methods:
We examined all patients with acute stroke treated with the Embotrap device from October 2013 to March 2017 in our center. Imaging parameters and times were adjudicated by core laboratory personnel blinded to clinical information, treating physician, and clinical outcomes. Clinical evaluation was performed by independent neurologists and entered in a national registry. Evaluated endpoints were: successful revascularization (modified Thrombolysis in Cerebral Infarction (mTICI) 2b-3) and good clinical outcomes at 3 months (modified Rankin Scale (mRS) 0-2).
Results:
201 consecutive patients with a median NIH Stroke Scale (NIHSS) score of 15 (range 2-30) were included. 170 patients (84.6%) achieved mTICI 2b-3 reperfusion. The median number of attempts was 2 (range 1-10) with 52.8% of the population achieving good functional outcomes (mRS 0-2) at 3 months. On univariate analysis, good functional outcome was associated with the number of attempts, puncture-to-reperfusion time, anterior circulation occlusion, and NIHSS score. On multivariate analysis, pre-treatment NIHSS (OR 0.845 per point, 95% CI 0.793 to 0.908, P<0.001) and puncture-to-reperfusion time (OR 0.9952 per min, 95% CI 0.9914 to 0.9975, P=0.023) were associated with good functional outcomes at 3 months.
Conclusion:
The Embotrap device has a high rate of successful reperfusion. Our core laboratory-audited single-center experience suggests the technical feasibility and safety of the Embotrap for first-line use in a real-world setting.
Related Concept Videos
The Nucleosome Core Particle
The paradox
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their main responsibility is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. While on the other hand, they must allow polymerase enzymes to access DNA...
The Nucleosome Core Particle
Nucleosomes, paradoxically, perform two opposite functions simultaneously. On the one hand, their primary aim is to protect the delicate DNA strands from physical damage and help achieve a higher compaction ratio. On the other hand, they must allow polymerase enzymes to access histone-bound DNA during...
Setting Time of Cement
Nursing Process for Patient and Caregiver Teaching I: Assessment and Diagnosis
It is critical to determine the patient's learning needs during the assessment. Determination of learning needs compounds data...
Specialized Care Centers and Settings-II
Rural health centers are specialized care facilities in remote locations with very few medical personnel. The primary care providers who run the centers are mostly Registered Nurse Practitioners. Here, emergency treatment is provided to critically ill or injured patients before they are transferred to the closest hospital. Fortunately, due to advancement in technology, many rural healthcare facilities and professionals have easy access to diagnostic and treatment...
PPE Use in Healthcare Settings I: Donning