Related Experiment Video
Updated: Feb 12, 2026

An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing
Christian Allende1, Fernando Vanoli2, Luciano Gentile2
1Instituto Allende de Cirugía Reconstructiva, Sanatorio Allende, Hipolito Yrigoyen 384, 5000, Córdoba, Argentina. christian_allende@hotmail.com.
Introduction:
The purpose of this study was to evaluate the results achieved after the use of lateral minimally invasive plate osteosynthesis (MIPO) in oligotrophic humerus nonunions resulting from failed intramedullary nailing (IM).
Method:
We evaluated nine patients with humerus nonunion after failed locked intramedullary nailing, all treated using 3.5-mm locked compression plates (LCP) placed through lateral minimally invasive approaches, between 2010 and 2016. Patient's age averaged 39.7 years. All nonunions were diaphyseal and oligotrophic. All nonunions had previous surgical treatment with static locked nails (seven antegrade and two retrograde). The IM nails were all well inserted in the humerus (none of them protruded or had rotator cuff lesions associated). Pre-operative Disabilities of the Arm, Shoulder and Hand (DASH) score averaged 25.5 points. Pre-operative Constant's score averaged 80.2. Pre-operative visual analog scale of pain averaged 2.4 points.
Results:
Follow-up averaged 17.7 months. Time between initial surgery and revision procedure averaged 11.7 months. Union was achieved in all cases, after an average of 4.8 months. DASH score at last follow-up averaged 5.1 points, and final Constant's score averaged 93.7 points. The analog scale of pain averaged 0.7 points. Time from definitive surgery to work return averaged 3.9 months. Long 3.5-mm LCPs were used (plate length averaged 16.9 screw holes). In two cases, a third 4-cm incision at the nonunion site was performed and cancellous autologous iliac crest bone graft was associated.
Conclusion:
In our series of nine patients, we achieved union and good objective and subjective results, with high patient satisfaction, using a lateral MIPO technique and placing long 3.5-mm LCPs in selected oligotrophic humerus nonunions after failed IM nailing.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
Related Concept Videos
Bones of the Upper Limb: Humerus
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Electric Field of Parallel Conducting Plates
Consider a cross-section of a thin, infinite conducting plate having a positive charge. For such a large thin plate, as the thickness of the plate tends to zero, the positive charges lie on the plate's two large faces. Without an external electric field, the...
Fluid Pressure over Curved Plate of Constant Width