Investigation of the Relationship Between Electrical Stimulation Frequency and Muscle Frequency Response Under
Caluê Papcke1, Eddy Krueger2,3, Marcia Olandoski4
1Graduate Program in Health Technology, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil.
Abstract:
Neuromuscular electrical stimulation (NMES) is a common tool that is used in clinical and laboratory experiments and can be combined with mechanomyography (MMG) for biofeedback in neuroprostheses. However, it is not clear if the electrical current applied to neuromuscular tissues influences the MMG signal in submaximal contractions. The objective of this study is to investigate whether the electrical stimulation frequency influences the mechanomyographic frequency response of the rectus femoris muscle during submaximal contractions. Thirteen male participants performed three maximal voluntary isometric contractions (MVIC) recorded in isometric conditions to determine the maximal force of knee extensors. This was followed by the application of nine modulated NMES frequencies (20, 25, 30, 35, 40, 45, 50, 75, and 100 Hz) to evoke 5% MVIC. Muscle behavior was monitored by the analysis of MMG signals, which were decomposed into frequency bands by using a Cauchy wavelet transform. For each applied electrical stimulus frequency, the mean MMG spectral/frequency response was estimated for each axis (X, Y, and Z axes) of the MMG sensor with the values of the frequency bands used as weights (weighted mean). Only with respect to the Z (perpendicular) axis of the MMG signal, the stimulus frequency of 20 Hz did not exhibit any difference with the weighted mean (P = 0.666). For the frequencies of 20 and 25 Hz, the MMG signal displayed the bands between 12 and 16 Hz in the three axes (P < 0.050). In the frequencies from 30 to 100 Hz, the muscle presented a higher concentration of the MMG signal between the 22 and 29 Hz bands for the X and Z axes, and between 16 and 34 Hz bands for the Y axis (P < 0.050 for all cases). We observed that MMG signals are not dependent on the applied NMES frequency, because their frequency contents tend to mainly remain between the 20- and 25-Hz bands. Hence, NMES does not interfere with the use of MMG in neuroprosthesis.
More Related Videos
08:01Measurement of Insulin- and Contraction-Stimulated Glucose Uptake in Isolated and Incubated Mature Skeletal Muscle from Mice
Published on: May 16, 2021
03:49Author Spotlight: Optimizing EAS with Long Electrodes for Enhanced Cochlear Coverage and Hearing Preservation
Published on: October 11, 2024
Related Concept Videos
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Frequency Response of BJT
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...
Frequency Response of a Circuit
The transfer function is pivotal in characterizing how these circuits react to various frequencies, facilitating a profound understanding of their behavior. An essential parameter is the time constant, signifying the...
Frequency-dependent Selection
Frequency Response of Op Amp Circuits
Frequency Response and Gain:
The gain of the op-amp, A(ω), is not a constant but a function of the input signal frequency. An op-amp can maintain a constant gain at low frequencies, known...
Muscle Contraction