Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Neutron-based computed microtomography: Pliobates cataloniae and Barberapithecus huerzeleri as a test-case study
Alessandro Urciuoli1, Clément Zanolli2, Josep Fortuny1,3
1Institut Català de Paleontologia Miquel Crusafont, Universitat Autònoma de Barcelona, Edifici ICTA-ICP, c/Columnes s/n, Campus de la UAB, 08193 Cerdanyola del Vallès, Barcelona, Spain.
Objectives:
High-resolution imaging of fossils with X-ray computed microtomography (μCT) has become a very powerful tool in paleontological research. However, fossilized bone, embedding matrix, and dental tissues do not always provide a distinct structural signal with X-rays. We demonstrate the benefits of high-resolution neutron radiation in three different specimens showing problematic contrasts with X-ray μCT.
Materials And Methods:
We compare neutron with X-ray μCT scans of fossils from two Miocene catarrhines from the Vallès-Penedès Basin: the cranium (IPS58443.1, holotype) of the putative stem hominoid Pliobates cataloniae, to discriminate between bone and matrix; and two lower molars (IPS1724n,o, holotype) of Barberapithecus huerzeleri, to discriminate among dental tissues.
Results:
X-ray μCT scans of these specimens fail to retrieve any contrast between matrix/bone and enamel/dentine, whereas neutron μCT scans deliver high-contrast images, enabling a proper evaluation of the specimens' internal anatomy.
Discussion:
Low bone/matrix intensity difference with X-ray μCT scans in IPS58443.1 is due to the extreme similarity in chemical composition between the matrix and the fossilized tissues, and the presence of high-density elements. In IPS1724, it is attributable to the convergence of enamel and dentine compositions during fossilization. On the contrary, neutron radiation returns very different contrasts for different isotopes of the same element and easily penetrates most metals. Neutron-based μCT scans therefore enable a correct definition of the bone/sediment and enamel/dentine interfaces, and hence a better segmentation of the images stack. We conclude that neutron radiation represents a successful alternative for high-resolution µCT of small-sized fossils that are problematic with X-rays.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Traverse Angle Computations
Area Computation by the Alternative Coordinate Method
The Role of Ion Channels in Neuronal Computation
Sometimes a single EPSP is strong enough to induce an action potential in the postsynaptic neuron. However, multiple presynaptic inputs must often create EPSPs around the same time for the postsynaptic neuron to be sufficiently depolarized to fire an action potential....
Case Studies