Related Experiment Video
Updated: Feb 12, 2026

Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
Venous and autonomic function in formerly pre-eclamptic women and controls matched for body mass index
W M Heidema1, J van Drongelen1, M E A Spaanderman2
1Department of Obstetrics and Gynecology, Radboud University Medical Centre, Nijmegen, The Netherlands.
Objective:
Prepregnancy reduced plasma volume (PV) increases the risk of subsequent pre-eclamptic pregnancy. Reduced PV is thought to reflect venous reserve capacity, especially when venous vasculature is constricted and sympathetic tone is elevated. As obesity might affect these variables, and is associated with pre-eclampsia, increased body weight may underlie these observations. The aim of this study was to determine whether the relationship between reduced venous reserve and pre-eclampsia is independent of body mass index (BMI).
Methods:
This was an observational case-control study in which venous reserve capacity in 30 formerly pre-eclamptic, but currently non-pregnant, women divided equally into three groups based on BMI (BMI 19.5-24.9, 25.0-29.9 or ≥ 30.0 kg/m2 ), was compared with that in 30 healthy parous, non-pregnant controls. Cases and controls were matched for BMI, age and parity. Venous reserve capacity was quantified by assessing PV and venous compliance (VeC). The autonomic nervous system regulating venous capacitance was evaluated using heart rate (HR) variability analysis, with the women in a resting supine position and during positive head-up tilt (HUT).
Results:
Compared with controls, formerly pre-eclamptic women had, when in a resting supine position, lower PV (1339 ± 79 vs 1547 ± 139 mL/m2 (P < 0.0001)), lower VeC (0.04 ± 0.02 vs 0.07 ± 0.02 mL/dL/mmHg (P < 0.0001)), higher sympathetic tone (1.9 ± 1.1 vs 1.2 ± 0.7 (P = 0.002)) and lower baroreceptor sensitivity (BRS; 8.7 ± 3.8 vs 19.0 ± 1.7 ms/mmHg (P < 0.0001)). During HUT, women with a history of pre-eclampsia had less modulatory capacity over VeC and BRS, while HR and sympathetic tone remained consistently higher.
Conclusions:
Women with a history of pre-eclampsia had reduced venous reserve capacity compared with that in BMI-matched controls. This is reflected by lower PV and VeC, with the autonomic balance being shifted towards sympathetic dominance and lower BRS. This suggests that underlying reduced venous reserve, but not BMI, relates to pre-eclampsia. Copyright © 2018 ISUOG. Published by John Wiley & Sons Ltd.
Related Concept Videos
Reduced Mass Coordinates: Isolated Two-body Problem
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Drug Control Governance: Regulatory Bodies and Their Impact
Transfer Function in Control Systems
To derive the transfer function, consider a general nth-order linear time-invariant...
Autonomic Nervous System
The ANS comprises two main divisions: the sympathetic and parasympathetic divisions. These divisions function antagonistically to maintain a dynamic...
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...

