Abstract:
This article proposes a novel dexterous endoscopic parallel manipulator for minimally invasive surgery. The proposed manipulator has 3 degrees of freedom (3-DOF), which consist of two rotational DOFs and one translational DOF (2R1T DOFs). The manipulator consists of 3 limbs exhibiting identical kinematic structure. Each limb contains an active prismatic joint followed by 2 consecutive passive universal joints. The proposed manipulator has a unique arrangement of its joints' axes. This unique arrangement permits large bending angles, ±90° in any direction, and a workspace almost free from interior singularities. These advantages allow the proposed manipulator to outperforms existing surgical manipulators. However, this unique arrangement makes the analysis of the robot extremely difficult. Therefore, a geometrical/analytical approach is used to facilitate its singularity analysis. Construction of the virtual prototype is accomplished using ADAMS software to validate the proposed manipulator and its bending capability. A closed-form solution for inverse kinematics is obtained analytically. Also, the forward kinematics solution is obtained numerically. Moreover, evaluation of the workspace is achieved using motion/force transmissibility indices. A practical experiment has been performed using a scaling technique and PID controller. The experimental results show the feasibility of the teleoperated surgical system using the proposed parallel manipulator as the slave.
More Related Videos
07:30Electromagnetic Navigation Transthoracic Nodule Localization for Minimally Invasive Thoracic Surgery
Published on: May 4, 2022
06:51Author Spotlight: Development of a Minimally Invasive Large-Animal Model for Reliable and Reproducible Cardiovascular Research
Published on: October 20, 2023
Related Concept Videos
Piaget's Stage 3 of Cognitive Development
Conservation and Constancy of Quantity
A significant cognitive milestone in the...
PPE Use in Healthcare Settings II: Doffing
Parallel Processing
Parallel Resonance
Resistors In Parallel
Series and Parallel Capacitors
First, consider capacitors connected in series to a battery. In this configuration, the plate connected to the battery's positive terminal develops a positive charge, while the plate attached to the negative terminal becomes negatively charged. An equal magnitude of charge is induced on the...