Related Experiment Video
Updated: Feb 12, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
The Use of Barbed Suture for Intracorporeal Mechanical Anastomosis During a Totally Laparoscopic Right Colectomy: Is
Umberto Bracale1, Giovanni Merola1,2, Francesco Cabras3
11 University Federico II of Naples, Naples, Italy.
Background:
A totally laparoscopic right colectomy could be perceived as a more challenging procedure over a laparoscopic-assisted right colectomy owing to the difficulty of intracorporeal anastomosis and the closure of the enterotomy. The aim of this study is to evaluate the safety and efficacy of the barbed auto-locking absorbable suture for the closure of an anastomotic stapler-access enterotomy during a totally laparoscopic right colectomy.
Methods:
From January 2010 to April 2016, data from patients who had undergone a laparoscopic right colectomy in 2 different departments of 2 institutions (the Department of General and Minimally Invasive Surgery, San Camillo Hospital in Trento and the Department of Surgical Specialties and Nephrology, University Federico II in Naples) were retrospectively analyzed. We compared the data of patients in whom the stapler-access enterotomy was closed through a conventional absorbable suture (Group A), with the data of patients in whom a stapler-access enterotomy was closed through a V-Loc 180 suture (Group B). Biometric features and intraoperative and postoperative data were collected and analyzed.
Results:
The 2 groups (Group A: 40 patients; Group B: 40 patients) were comparable for biometric features and postoperative outcomes. The anastomosing time was lower in Group B. A statistically significant difference was noted in the mean operative time between Groups A and B (Group A = 134.92 ± 34.17; Group B = 120.92 ± 23.27, P = .035). Only one anastomotic leakage per group was recorded, each treated with an anastomosis redo. During the reoperations, we find in both groups an intact stapler-access enterotomy.
Conclusion:
On retrospective analysis, barbed suture appears to be safe and efficient for closure of the stapler-access enterotomy during totally laparoscopic right colectomy.
Related Concept Videos
Sutures of the Skull
Sutures are immobile joints between adjacent bones of the skull. The narrow gap between the bones is filled with dense, fibrous connective tissue that unites the bones. The long sutures located between the skull bones are not straight but instead follow irregular, tightly twisting paths. These twisting lines tightly...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Total Voids in Concrete
Comparative Excretory Systems
Comparing Experimental Results: Student's t-Test