Rigid Plate Fixation Versus Wire Cerclage for Sternotomy After Cardiac Surgery: A Meta-Analysis
Derrick Y Tam1, Rashmi Nedadur2, Monica Yu3
1Division of Cardiac Surgery, Department of Surgery, Sunnybrook Health Sciences Center, University of Toronto, Toronto, Ontario, Canada; Institute of Health Policy, Management, and Evaluation, University of Toronto, Toronto, Ontario, Canada.
Background:
Traditionally, wire cerclage has been used to reapproximate the sternum after sternotomy. Recent evidence suggests that rigid plate fixation for sternal closure may reduce the risk of sternal complications.
Methods:
The Medline and Embase databases were searched from inception to February 2017 for studies that compared rigid plate fixation with wire cerclage for cardiac surgery patients undergoing sternotomy. Random effects meta-analysis compared rates of sternal complications (primary outcome, defined as deep or superficial sternal wound infection, or sternal instability), early mortality, and length of stay (secondary outcomes).
Results:
Three randomized controlled trials (n = 427) and five unadjusted observational studies (n = 1,025) met inclusion criteria. There was no significant difference in sternal complications with rigid plate fixation at a median of 6 months' follow-up (incidence rate ratio 0.51, 95% confidence interval [CI]: 0.20 to 1.29, p = 0.15) overall, but a decrease when including only patients at high risk for sternal complications (incidence rate ratio 0.23, 95% CI: 0.06 to 0.89, p = 0.03; two observational studies). Perioperative mortality was reduced favoring rigid plate fixation (relative risk 0.40, 95% CI: 0.28 to 0.97, p = 0.04; four observational studies and one randomized controlled trial). Length of stay was similar overall (mean difference -0.77 days, 95% CI: -1.65 to +0.12, p = 0.09), but significantly reduced with rigid plate fixation in the observational studies (mean difference -1.34 days, 95% CI: -2.05 to -0.63, p = 0.0002).
Conclusions:
This meta-analysis, driven by the results of unmatched observational studies, suggests that rigid plate fixation may lead to reduced sternal complications in patients at high risk for such events, improved perioperative survival, and decreased hospital length of stay. More randomized controlled trials are required to confirm the potential benefits of rigid plate fixation for primary sternotomy closure.
Related Concept Videos
Directing Effect of Substituents: meta-Directing Groups
Rigid Body Equilibrium Problems - I
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Rigid Body Equilibrium Problems - II
Consider two children sitting on a seesaw, which has negligible mass. The first child has a mass (m1) of 26 kg and sits at point A, which is 1.6 meters (r1) from the pivot point B; the second child has a mass (m2) of 32 kg and sits at point C. How far from the pivot point B should the second child sit (r2) to balance the seesaw?
Magnetic Field Due to Two Straight Wires
Household Wiring And Electrical Safety