Related Experiment Video
Updated: Feb 12, 2026

The Role of Fabric in Frictional Properties of Phyllosilicate-Rich Tectonic Faults
Published on: November 6, 2021
Local Conduction in Mo xW1- xSe2: The Role of Stacking Faults, Defects, and Alloying
Pantelis Bampoulis1, Kai Sotthewes1, Martin H Siekman1
1Physics of Interfaces and Nanomaterials, MESA+ Institute for Nanotechnology , University of Twente , P.O. Box 217, 7500AE Enschede , The Netherlands.
Abstract:
Here, we report on the surface conductivity of WSe2 and Mo xW1- xSe2 (0 ≤ x ≤ 1) crystals investigated with conductive atomic force microscopy. We found that stacking faults, defects, and chemical heterogeneities form distinct two-dimensional and one-dimensional conduction paths on the transition metal dichalcogenide surface. In the case of WSe2, in addition to step edges, we find a significant amount of stacking faults (formed during the cleaving process) that strongly influence the surface conductivity. These regions are attributed to the alternation of the 2H and 3R polytypism. The stacking faults form regular 2D patterns by alternation of the underlying stacking order, with a periodicity that varies significantly between different regions and samples. In the case of Mo xW1- xSe2, its conductivity has a localized nature, which depends on the underlying chemical composition and the Mo/W ratio. Segregation to W-rich and Mo-rich regions during the growth process leads to nonuniform conduction paths on the surface of the alloy. We found a gradual change of the conductivity moving from one region to the other, reminiscent of lateral band bending. Our results demonstrate the use of C-AFM as a nanoscopic tool to probe the electrical properties of largely inhomogeneous samples and show the complicated nature of the surface conductivity of TMDC alloys.
Related Concept Videos
Fault Types
For line-to-line faults occurring between phases B and C, the...
Local Anesthetics: Clinical Application as Surface, Infiltration, and Conduction Block Anesthesia
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Conduct Disorder
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...

