Related Experiment Video
Updated: Feb 12, 2026

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water
Published on: August 3, 2016
Investigating the Effect of Bioirrigation on In Situ Porewater Concentrations and Fluxes of Polychlorinated Biphenyls
Jennifer N Apell1, David H Shull2, Alison M Hoyt1
1R.M. Parsons Laboratory, Department of Civil and Environmental Engineering , Massachusetts Institute of Technology , Cambridge , Massachusetts 02139 , United States.
Abstract:
Polychlorinated biphenyl (PCB) fluxes from contaminated sediments can be caused by mechanisms including diffusion, bioirrigation, and resuspension, but it is often unclear which mechanisms are important. In the Lower Duwamish Waterway (Seattle, Washington), the presence of abundant benthic macrofauna suggests that porewater bioirrigation may be an important mechanism for PCB transport from the bed into the overlying water column. In this field study, the fluxes of PCBs due to bioirrigation were quantified by using (a) polyethylene (PE) samplers to quantify in situ and ex situ (i.e., equilibrium) PCB porewater concentration profiles and (b) measurements of the geochemical tracer 222Rn to quantify the rate of porewater exchange with overlying water. The results showed that bioirrigation caused sorptive disequilibrium with the surrounding sediment, which led to lower in situ porewater concentrations than expected from sediment concentrations. The combined fluxes of seven PCB congeners (Σ7PCBs) were 1.6-26 ng/m2/day for the three field sites, similar in magnitude to the upper limit estimates of diffusive fluxes calculated assuming water-side boundary layer control (Σ7PCBs = 1.3-47 ng/m2/day). Moreover, the depleted in situ porewater concentrations imply lower diffusive flux estimates than if the ex situ porewater concentrations had been used to estimate fluxes (Σ7PCBs = 89-670 ng/m2/day). These results suggest that nondiffusive PCB fluxes from the sediment bed are occurring and that quantifying in situ porewater concentrations is crucial for accurately quantifying both diffusive and nondiffusive PCB fluxes.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
08:55Methods of Ex Situ and In Situ Investigations of Structural Transformations: The Case of Crystallization of Metallic Glasses
Published on: June 7, 2018
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Electric Flux
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Concentration Cells
Consider the following voltaic cell:
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
Passive Diffusion: Overview and Kinetics
When administered orally, drugs establish a substantial concentration gradient between the gastrointestinal (GI) lumen and the bloodstream, expediting...