Intensity modulated operating mode of the rotating gamma system
Bishwambhar Sengupta1, Laszlo Gulyas2, Donald Medlin1
1Department of Physics and Astronomy, Clemson University, Clemson, SC, 29634, USA.
Novel rotating gamma systems (RGS) modalities, intensity modulated radiosurgery (IMRS) and speed modulated radiosurgery (SMRS), offer precise dose modulation. These techniques provide highly constrained dose distributions, expanding clinical applications for treating lesions near critical organs at risk (OAR).
Area of Science:
- Medical Physics
- Radiation Oncology
- Radiosurgery Technology
Background:
- Rotating gamma systems (RGS) are advanced tools in radiation therapy.
- Expanding RGS clinical applications requires exploring novel operation modalities.
- Treating lesions near critical organs at risk (OAR) necessitates precise dose delivery.
Purpose of the Study:
- To investigate two new RGS operation modalities: intensity modulated radiosurgery (IMRS) and speed modulated radiosurgery (SMRS).
- To assess the potential of these novel modalities for treating lesions close to OARs.
- To evaluate the dosimetric properties and clinical applicability of IMRS and SMRS.
Main Methods:
- Utilized Geant4-based Monte Carlo (MC) simulations to model RGS Vertex 360™ dosimetric properties.
- Modeled normal, IMRS, and SMRS operation modalities.
- Collected experimental data using an ion chamber for absolute dose and Gafchromic EBT3 films for dose profiles.
Main Results:
- Demonstrated strong dosimetric agreement between simulated and measured dose profiles and penumbra for normal and IMRS modes.
- Observed ellipsoidal dose distributions for IMRS and SMRS, with sharper penumbra along the short axes.
- Found that dose distributions are highly constrained, particularly for smaller collimator sizes.
Conclusions:
- Confirmed that IMRS and SMRS enable dose modulation in RGS.
- Highlighted the clinical applicability of these modes for treating lesions near critical OARs due to constrained dose delivery.
- Emphasized the potential of IMRS and SMRS to improve treatment precision and safety in radiosurgery.
Related Concept Videos
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Sound Intensity
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....