Minimal starting time of data reconstruction for qualitative myocardial perfusion rubidium-82 positron emission
Joris D van Dijk1,2, Eline D Huizing1,2, Jorn A van Dalen3
1Departments of Nuclear Medicine.
Objective:
Qualitative positron emission tomography (PET) myocardial perfusion imaging (MPI) scans are reconstructed with a delay after an injection of rubidium-82 (Rb) to ensure blood pool clearance and sufficient left ventricle to myocardium contrast. Our aim was to derive the minimal starting time of data reconstruction (STDR) after an injection of Rb for which the diagnostic value and image quality remained unaffected.
Materials And Methods:
We retrospectively included 23 patients who underwent rest-stress Rb PET MPI using 740 MBq. Patients fulfilling one of the two criteria indicating a slow blood pool clearance (ejection fraction <50% and/or cardiac output <3 l/min) were included in a consecutive manner. PET images using five different STDRs (1:15-2:15 min) were reconstructed and compared with reference images (STDR of 2:30 min). Differences in the summed rest score greater than or equal to 3 and total perfusion deficit greater than 3% were considered to significantly influence the diagnostic value. In addition, image quality was scored by two experts as not interpretable, inferior, adequate, or excellent.
Results:
The summed rest score differed greater than or equal to 3 from the reference in seven or more patients (≥30%) using STDR less than or equal to 2:00 min (P<0.02). STDR less than or equal to 1:30 min resulted in six or more patients (≥26%) with a total perfusion deficit difference greater than 3% (P<0.03).In addition, STDR less than or equal to 2:00 min resulted in a lower image quality (P<0.002) and STDR less than or equal to 2:15 min resulted in greater than or equal to two scans with noninterpretable image quality.
Conclusion:
STDR less than or equal to 2:15 min resulted in lower diagnostic value or insufficient image quality for qualitative PET MPI using 740 MBq Rb. An STDR of 2:30 min can be considered for clinical adoption.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
10:31Non-invasive Imaging and Analysis of Cerebral Ischemia in Living Rats Using Positron Emission Tomography with 18F-FDG
Published on: December 28, 2014
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Qualitative Analysis
For instance, group IV...
Qualitative Analysis
There are two main approaches to qualitative analysis:...
Emission Spectra