Related Experiment Video
Updated: Feb 12, 2026

How to Obtain Reliable Visual Event-related Potentials in Newborns
Published on: October 24, 2019
Recommendations for newborn screening for galactokinase deficiency: A systematic review and evaluation of Dutch
Kevin Stroek1, Marelle J Bouva2, Peter C J I Schielen2
1Department of Clinical Chemistry, Laboratory of Endocrinology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Introduction:
Galactokinase (GALK) deficiency causes cataract leading to severe developmental consequences unless treated early. Because of the easy prevention and rapid reversibility of cataract with treatment, the Dutch Health Council advised to include GALK deficiency in the Dutch newborn screening program. The aim of this study is to establish the optimal screening method and cut-off value (COV) for GALK deficiency screening by performing a systematic review of the literature of screening strategies and total galactose (TGAL) values and by evaluating TGAL values in the first week of life in a cohort of screened newborns in the Netherlands.
Methods:
Systematic literature search strategies in OVID MEDLINE and OVID EMBASE were developed and study selection, data collection and analyses were performed by two independent investigators. A range of TGAL values measured by the Quantase Neonatal Total Galactose screening assay in a cohort of Dutch newborns in 2007 was evaluated.
Results:
Eight publications were included in the systematic review. All four studies describing screening strategies used TGAL as the primary screening marker combined with galactose-1-phosphate uridyltransferase (GALT) measurement that is used for classical galactosemia screening. TGAL COVs of 2200 μmol/L, 1665 μmol/L and 1110 μmol/L blood resulted in positive predictive values (PPV) of 100%, 82% and 10% respectively. TGAL values measured in the newborn period were reported for 39 GALK deficiency patients with individual values ranging from 3963 to 8159 μmol/L blood and 2 group values with mean 8892 μmol/L blood (SD ± 5243) and 4856 μmol/L blood (SD ± 461). Dutch newborn screening data of 72,786 newborns from 2007 provided a median TGAL value of 110 μmol/L blood with a range of 30-2431 μmol/L blood.
Conclusion:
Based on TGAL values measured in GALK deficiency patients reported in the literature and TGAL measurements in the Dutch cohort by newborn screening we suggest to perform the GALK screening with TGAL as a primary marker with a COV of 2500 μmol/L blood, combined with GALT enzyme activity measurement as used in the classical galactosemia screening, to ensure detection of GALK deficiency patients and minimize false positive referrals.
Related Concept Videos
Genetic Screens
Forward genetic screens
Forward or “classical” genetic screens involve creating random mutations in an organism’s DNA using radiation, mutagens, or insertion of additional bases, which...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Random and Systematic Errors
Systematic Sampling Method
Systematic sampling is one of the simplest methods...
Propagation of Uncertainty from Systematic Error

