Related Experiment Video
Updated: Feb 12, 2026

Osmotic Drug Delivery to Ischemic Hindlimbs and Perfusion of Vasculature with Microfil for Micro-Computed Tomography Imaging
Published on: June 29, 2013
Evaluating the Feasibility of Isolated Pancreatic Perfusion for Chemotherapy Using Computed Tomography: An
Satoru Murata1, Shiro Onozawa2, Daisuke Yasui3
1Radiology/Center for Interventional Radiology, Teikyo University Chiba Medical Center, 3426-3 Anesaki, Ichihara, Chiba, 299-0111, Japan. nippgenji@gmail.com.
Purpose:
Percutaneous isolated pancreatic perfusion (PIPP) is performed along with interventional radiology techniques to obtain high drug concentration by occluding the arterial inlet and venous outlet of the pancreas. The experimental study aimed to evaluate the contrast distribution in PIPP under different flow rates with or without anterior mesenteric artery (AMA) occlusion.
Materials And Methods:
This study was approved by a local animal experiment ethics committee. Nine pigs were divided into Groups 1, 2, and 3, by infusion rates of 12, 24, and 36 mL/min. Groups 4 and 5 (3 pigs each) and Group 6 (2 pigs) underwent PIPP at the same respective infusion rates with and without AMA occlusion. Computed tomography (CT) arteriography was performed during PIPP with nonionic contrast media. The enhanced volume was calculated by adding the enhanced area in each slice using 1.25-mm axial images. The percent enhanced volume to the whole pancreas (%eV) was used to simulate drug distribution; the result was compared among groups.
Results:
Without AMA occlusion, a larger %eV was obtained with high infusion rates (P = 0.039). The median %eV in Groups 1, 2, and 3 were 57.7, 74.2, and 90.5%, respectively. With AMA occlusion, CT demonstrated duodenal enhancement at an infusion rate of 36 mL/min, and the median %eV in Groups 4, 5, and 6 were 92.8, 95.4, and 98.5%, respectively. A significantly larger %eV was obtained after AMA occlusion (P = 0.031).
Conclusion:
A higher infusion rate or AMA occlusion increases the enhanced volume in PIPP in pig models.
Level Of Evidence:
No level of evidence.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Self-Evaluation Maintenance Model
Chemotherapy-Induced Nausea and Vomiting: Cannabinoids
Two synthetic agonists of THC,...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...

