Influence of tube potential on quantitative coronary plaque analyses by low radiation dose computed tomography: a
Chunhong Wang1, Yuliang Liao2, Haibin Chen2
1Department of Radiology, Xinyang Central Hospital, Xinyang, 464002, Henan, China.
Abstract:
Previous studies have shown that employing the low dose computed tomography (CT) technique based on low tube potential reduces the radiation dose required for the coronary artery examination protocol. However, low tube potential may adversely influence the CT number of plaque composition. Therefore, we aimed to determine whether quantitative atherosclerotic plaque analysis by a multi-slice, low radiation dose CT protocol using 80 kilovolts (kV) yields results comparable to those of the standard 120 kV protocol. Artificial plaque samples (n = 17) composed of three kinds of plaque were scanned at 120 and 80 kV. Relative low-density and medium-density plaque component volumes obtained by three protocols (80 kV, 60 Hounsfield units [HU] threshold; 120 kV, 60 HU threshold; and 80 kV, 82 HU threshold) were compared. Using the 60 HU threshold, relative volume of the low-density plaque component obtained at 80 kV was lower than that obtained at 120 kV (27 ± 3% vs. 51 ± 5%, P < 0.001), whereas relative volume of the medium-density plaque component obtained at 80 kV was higher than that obtained at 120 kV (73 ± 3% vs. 48 ± 5%, P < 0.001). By contrast, no significant difference in relative volume obtained at 80 kV (82 HU threshold) versus 120 kV (60 HU threshold) was observed for either low-density (52 ± 5% vs. 51 ± 5%) or medium-density (48 ± 5% vs. 48 ± 5%) plaque component. Low tube potential may affect the accuracy of quantitative atherosclerotic plaque analysis. For our phantom test, 82 HU was the optimal threshold for scanning at 80 kV.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Biological Effects of Radiation
Bioavailability Study Design: Single Versus Multiple Dose Studies
Acute Coronary Syndrome III: Diagnostic Studies
Radiation: Applications
The average...