Engineering Antiviral Agents via Surface Plasmon Resonance
Published on: June 14, 2022
Dual-Valve and Counter-Flow Surface Plasmon Resonance
1College of Chemistry and Chemical Engineering , Central South University , Changsha , Hunan P. R. China , 410083.
This study introduces an alternate injection mode for surface plasmon resonance (SPR) instruments, enabling faster analysis and improved surface reactions for biomolecular binding studies. The novel method enhances ligand immobilization and stability, crucial for detecting small molecule interactions.
Area of Science:
- Analytical Chemistry
- Biochemistry
- Biotechnology
Background:
- Surface Plasmon Resonance (SPR) is a label-free optical sensing technique widely used for studying biomolecular interactions.
- Traditional SPR instruments often face limitations in analysis speed and surface reaction efficiency due to single-injector systems.
- Efficient ligand immobilization and stable surfaces are critical for sensitive SPR detection, especially for small molecules.
Purpose of the Study:
- To develop and demonstrate a novel alternate injection mode for SPR instruments.
- To enhance the speed and efficiency of surface reactions, including ligand immobilization and regeneration.
- To improve the sensitivity and reliability of SPR-based kinetic and affinity measurements.
Main Methods:
- Integration of two six-port injector valves and one selector valve with an SPR instrument.
- Implementation of a counter-flow system within the flow cell for simultaneous or sequential solution introduction.
- Utilizing the alternate injection mode for rapid (<1 s) exchange of solutions between fluidic channels.
- Demonstration with binding studies of acetazolamide to human carbonic anhydrase II and microglobulin to immobilized antibodies.
Main Results:
- The alternate injection mode significantly reduces analysis time and facilitates efficient ligand immobilization.
- Achieved higher ligand densities and more stable surfaces, crucial for SPR detection of small molecules.
- Demonstrated successful kinetic and affinity measurements without repeated dissociation and regeneration steps, as shown in acetazolamide-HCA and microglobulin-antibody binding assays.
Conclusions:
- The developed alternate injection mode offers a versatile and efficient approach for SPR analysis.
- This method enhances surface reaction capabilities, leading to improved sensitivity and reduced analysis time.
- The system is well-suited for kinetic and affinity studies, particularly for small molecule interactions and antibody-based assays.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse I: Introduction
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Resonance
Surface Tension and Surface Energy
Consider a beaker filled with liquid. The bulk molecules in the liquid experience equal attractive forces on all sides with the surrounding molecules. However, the surface molecules experience a net attractive force downward due to the bulk molecules. The surface of the liquid behaves like a stretched membrane,...
Series Resonance