Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping
Published on: November 7, 2016
Embedded Distributed Optical Fiber Sensors in Reinforced Concrete Structures-A Case Study
António Barrias1, Joan R Casas2, Sergi Villalba3
1Department of Civil and Environmental Engineering, Technical University of Catalonia (UPC), c/Jordi Girona 1-3, 08034 Barcelona, Spain. antonio.jose.de.sousa@upc.edu.
Distributed optical fiber sensors (DOFS) offer a robust method for monitoring reinforced concrete structures. Polyimide-coated DOFS bonded directly to rebars accurately measure strain during loading and cracking, simplifying deployment.
Area of Science:
- Structural Health Monitoring
- Materials Science
- Civil Engineering
Background:
- Accurate strain measurement in reinforced concrete is crucial for structural health monitoring.
- Distributed optical fiber sensors (DOFS) offer potential for robust, embedded sensing.
- Balancing sensor protection with measurement accuracy in cracked concrete is challenging.
Purpose of the Study:
- To evaluate the performance of polyimide-coated DOFS for monitoring reinforced concrete structures.
- To assess the accuracy of DOFS during loading, unloading, and reloading cycles, including cracking.
- To determine the feasibility of direct bonding of DOFS to rebars without complex preparation.
Main Methods:
- Two concrete beams instrumented with polyimide-coated DOFS bonded to rebars and concrete surfaces.
- Three-point bending tests were conducted, including loading, unloading, and reloading phases.
- Rayleigh Optical Frequency Domain Reflectometry (OFDR) was used for sensing.
- Strain gauges were co-located with DOFS for validation.
Main Results:
- Polyimide-coated DOFS can be reliably bonded directly to reinforcing bars without indention.
- Accurate strain measurements were achieved in both uncracked and cracked concrete stages.
- DOFS demonstrated capability in capturing strain variations during cyclic loading processes.
Conclusions:
- Thin-coated polyimide DOFS are feasible for direct bonding to rebars in reinforced concrete.
- The proposed Spectral Shift Quality (SSQ) threshold can aid in data interpretation for polyimide-coated DOFS.
- This method simplifies sensor deployment while maintaining measurement accuracy for structural health monitoring.
More Related Videos
Related Concept Videos
Fiber Reinforced Concrete
Design Example: Distributing Reinforcements in Concrete Sections
Reinforcements in Concrete
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Reinforcement
Positive reinforcement occurs when a behavior is followed by the presentation of a rewarding stimulus, increasing the frequency of that behavior. For example:
Classification of Skeletal Muscle Fibers
Slow-Twitch Muscle Fibers
Slow oxidative, muscle fibers appear red due to large numbers of capillaries and high levels of...