Macular photostress and visual experience between microscope and intracameral illumination during cataract surgery
Hyejin Seo1, Dong Heun Nam1, Jong Yeon Lee1
1From the Department of Ophthalmology (Seo, Nam, Lee, Park, Y.J. Kim), Gachon University Gil Hospital, Incheon, the Department of Ophthalmology (S.-W. Kim), Korea University College of Medicine, and the Department of Ophthalmology (Chung), Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea; the Kyorin Eye Center (Inoue), Kyorin University School of Medicine, Mitaka, Tokyo, Japan; the Department of Ophthalmology (T. Kim), Duke University Eye Center, Durham, North Carolina, USA.
Purpose:
To evaluate macular photostress and visual experience between coaxial microscope illumination versus oblique intracameral illumination during cataract surgery.
Setting:
Gachon University Gil Hospital, Incheon, South Korea.
Design:
Prospective case series.
Methods:
Consecutive patients who had cataract surgery using microscope illumination and intracameral illumination were included. The patients were asked to complete a questionnaire (seeing strong lights, feeling photophobia, feeling startled (fright) when seeing lights, seeing any colors, seeing any instruments or surgical procedures, and estimating intraoperative visual function) designed to describe their cataract surgery experience. The images projected on the retina of the model eye (rear view) with artificial opaque fragments in the anterior chamber during simulating cataract surgery were compared between the 2 illumination types.
Results:
Sixty patients completed the questionnaire. Scores for strong lights, photophobia, fright, and color perception were significantly higher with microscope illumination than with intracameral illumination (all P < .001). More patients preferred the intracameral illumination (45 [75.0%]) to the microscope illumination (13 [21.7%]). In the rear-view images created in a model eye, only the bright microscope light in the center was seen without any lens image in the microscope illumination. However, in the intracameral illumination, the less bright light from the light pipe in the periphery and the lens fragments were seen more clearly.
Conclusions:
In a view of the patients' visual experience, oblique intracameral illumination caused less subjective photostress and was preferred over coaxial microscope illumination. Objective findings from the model-eye experiment correlated to the result of visual experience.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
06:19Author Spotlight: A Novel Protocol for Intracameral Injections to Enhance Precision in Rodent Ophthalmology
Published on: May 31, 2024
Related Concept Videos
What is an Experiment?
Thomson's e/m Experiment
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
Controls in Experiments
Randomized Experiments
Simple randomization
Simple...
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
The Stanford Prison Experiment