Related Experiment Video
Updated: Feb 12, 2026

An Experimental Model of Diet-Induced Metabolic Syndrome in Rabbit: Methodological Considerations, Development, and Assessment
Published on: April 20, 2018
CLPP deficiency protects against metabolic syndrome but hinders adaptive thermogenesis
Christina Becker1, Alexandra Kukat1, Karolina Szczepanowska1
1Cologne Excellence Cluster on Cellular Stress Responses in Aging-Associated Diseases (CECAD) and Institute for Mitochondrial Diseases and Aging, Medical Faculty, University of Cologne, Cologne, Germany.
Abstract:
Mitochondria are fundamental for cellular metabolism as they are both a source and a target of nutrient intermediates originating from converging metabolic pathways, and their role in the regulation of systemic metabolism is increasingly recognized. Thus, maintenance of mitochondrial homeostasis is indispensable for a functional energy metabolism of the whole organism. Here, we report that loss of the mitochondrial matrix protease CLPP results in a lean phenotype with improved glucose homeostasis. Whole-body CLPP-deficient mice are protected from diet-induced obesity and insulin resistance, which was not present in mouse models with either liver- or muscle-specific depletion of CLPP However, CLPP ablation also leads to a decline in brown adipocytes function leaving mice unable to cope with a cold-induced stress due to non-functional adaptive thermogenesis. These results demonstrate a critical role for CLPP in different metabolic stress conditions such as high-fat diet feeding and cold exposure providing tools to understand pathologies with deregulated Clpp expression and novel insights into therapeutic approaches against metabolic dysfunctions linked to mitochondrial diseases.
More Related Videos
Related Concept Videos
What is Metabolism?
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protecting Self-Esteem
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...

