Accuracy of tumor segmentation from multi-parametric prostate MRI and 18F-choline PET/CT for focal prostate cancer

Morand Piert1,2, Prasad R Shankar3, Jeffrey Montgomery4

  • 1Radiology Department, University of Michigan, Ann Arbor, MI, USA. mpiert@med.umich.edu.

EJNMMI Research
|March 29, 2018
PubMed
Abstract

Insights

Accurate tumor segmentation for prostate cancer is challenging, with MRI and PET/CT methods underestimating volumes. Combining multi-parametric MRI (mpMRI) and 18F-choline PET/CT improves tumor coverage for focal therapies.

Area of Science:

  • Radiology
  • Oncology
  • Medical Imaging

Background:

  • Clinically significant prostate cancer requires accurate tumor delineation for effective treatment.
  • Multi-parametric MRI (mpMRI) and 18F-choline PET/CT are advanced imaging modalities for prostate cancer assessment.
  • Accurate segmentation of tumor volumes is crucial for planning focal therapies.

Purpose of the Study:

  • To evaluate the accuracy of mpMRI and 18F-choline PET/CT in segmenting tumor volumes in prostate cancer.
  • To compare manual mpMRI segmentation with semi-automatic 18F-choline PET/CT segmentation against histopathology.
  • To determine the effectiveness of combining imaging modalities for improved tumor coverage.

Main Methods:

  • Prospective study involving 10 patients with biopsy-confirmed Gleason ≥3+4 prostate cancer.
  • 3T mpMRI and 18F-choline PET/CT performed prior to radical prostatectomy.
  • Tumor boundaries delineated manually on mpMRI and semi-automatically on PET/CT, compared to whole-mount pathology.
  • Analysis of segmentation accuracy using overlap and similarity coefficients and underestimation percentages.

Main Results:

  • All segmentation methods significantly underestimated true tumor volumes (mpMRI: 79-80%, PET/CT: 58%).
  • Combining mpMRI and PET/CT segmentations reduced underestimation to 42%, further improved with contour expansion.
  • A 5mm contour expansion on combined segmentations reduced mean underestimation to 2.04%.
  • Combining modalities reduced the required safety margin to 9mm, compared to 11-15mm for individual methods.

Conclusions:

  • mpMRI alone significantly underestimates prostate cancer tumor volumes.
  • Integrating 18F-choline PET/CT metabolic data with mpMRI-based segmentation enhances tumor volume coverage.
  • This combined approach shows promise for improving focal therapy outcomes but requires further clinical validation.

Related Concept Videos

Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
921
Cancer Therapies02:49

Cancer Therapies

Cancer therapies are various modes of treatment, such as surgery, radiation therapy, and chemotherapy that are administered to cancer patients.
However, cancer treatments can pose several challenges, as therapies used to kill cancer cells are generally also toxic to normal cells. Moreover, cancer cells mutate rapidly and can develop resistance to chemical agents or radiation therapy. Besides, all types of cancer cells may not respond to the same therapy. Some cancer cells respond to one...
10.2K
Targeted Cancer Therapies02:57

Targeted Cancer Therapies

The targeted cancer therapies, also known as “molecular targeted therapies,” take advantage of the molecular and genetic differences between the cancer cells and the normal cells. It needs a thorough understanding of the cancer cells to develop drugs that can target specific molecular aspects that drive the growth, progression, and spread of cancer cells without affecting the growth and survival of other normal cells in the body.
There are several types of targeted therapies against...
9.0K
Improving Translational Accuracy02:07

Improving Translational Accuracy

Base complementarity between the three base pairs of mRNA codon and the tRNA anticodon is not a failsafe mechanism. Inaccuracies can range from a single mismatch to no correct base pairing at all. The free energy difference between the correct and nearly correct base pairs can be as small as 3 kcal/ mol. With complementarity being the only proofreading step, the estimated error frequency would be one wrong amino acid in every 100 amino acids incorporated. However, error frequencies observed in...
15.0K
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
104.7K
Accuracy and Precision01:52

Accuracy and Precision

Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.  Highly accurate...
15.7K