Related Experiment Video
Updated: Feb 12, 2026

Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
Published on: March 7, 2019
Validity and reliability of an inertial device (WIMU PROTM) to quantify physical activity level through steps
Alejandro Hernández-Belmonte1, Alejandro Bastida-Castillo1, Carlos D Gómez-Carmona2,3
1Physical Activity and Sport Department, University of Murcia, Murcia, Spain.
Background:
Currently, there is an increase in the application of accelerometers to quantify physical activity level through daily steps, and therefore, it is required that the devices are valid and reliable. The current study tested the validity of the WIMU PROTM inertial device in steps detection and the inter-device reliability for steps measurement.
Methods:
Ten endurance-trained men volunteered to participate in this study (height: 1.78±0.05 m; body mass: 72.96±4.2 kg). Twelve trials of 40.32 m at different speeds (four trials at each speed) were performed: 1) walking (<5 km/h); 2) jogging (5-10 km/h) and running (10-15 km/h). The video analysis was used as criterion to assess validity, while, two WIMU PROTM inertial devices were compared to assess between-unit reliability.
Results:
A near-perfect validity between video analysis and WIMU PROTM (ICC=0.999; bias=0.03) and a very good reliability between WIMU PROTM devices (bias=-0.01; CV=0.02%) was found. The highest values were found at walking (ICC=0.999) and the lowest values were found at running (ICC=0.995).
Conclusions:
WIMU PROTM is a reliable and valid device to quantify physical activity level through steps measurement.
More Related Videos
09:18Feeding Experimentation Device FED: Construction and Validation of an Open-source Device for Measuring Food Intake in Rodents
Published on: February 21, 2017
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Related Concept Videos
Reliability and Validity
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...
Quantifying Work