Accuracy of Bioelectrical Impedance Analysis in Estimated Longitudinal Fat-Free Mass Changes in Male Army Cadets
Related Experiment Video
Updated: Feb 12, 2026

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
Published on: August 17, 2022
Raquel D Langer1, Catarina N Matias2, Juliano H Borges1
1Laboratory of Growth and Development - Center for Investigation in Pediatrics (CIPED), University of Campinas, Campinas, Brazil.
Introduction:
Bioelectrical impedance analysis (BIA) is a practical and rapid method for making a longitudinal analysis of changes in body composition. However, most BIA validation studies have been performed in a clinical population and only at one moment, or point in time (cross-sectional study). The aim of this study is to investigate the accuracy of predictive equations based on BIA with regard to the changes in fat-free mass (FFM) in Brazilian male army cadets after 7 mo of military training. The values used were determined using dual-energy X-ray absorptiometry (DXA) as a reference method.
Materials And Methods:
The study included 310 male Brazilian Army cadets (aged 17-24 yr). FFM was measured using eight general predictive BIA equations, with one equation specifically applied to this population sample, and the values were compared with results obtained using DXA. The student's t-test, adjusted coefficient of determination (R2), standard error of estimation (SEE), Lin's approach, and the Bland-Altman test were used to determine the accuracy of the predictive BIA equations used to estimate FFM in this population and between the two moments (pre- and post-moment).
Results:
The FFM measured using the nine predictive BIA equations, and determined using DXA at the post-moment, showed a significant increase when compared with the pre-moment (p < 0.05). All nine predictive BIA equations were able to detect FFM changes in the army cadets between the two moments in a very similar way to the reference method (DXA). However, only the one BIA equation specific to this population showed no significant differences in the FFM estimation between DXA at pre- and post-moment of military routine. All predictive BIA equations showed large limits of agreement using the Bland-Altman approach.
Conclusion:
The eight general predictive BIA equations used in this study were not found to be valid for analyzing the FFM changes in the Brazilian male army cadets, after a period of approximately 7 mo of military training. Although the BIA equation specific to this population is dependent on the amount of FFM, it appears to be a good alternative to DXA for assessing FFM in Brazilian male army cadets.
More Related Videos
07:44Author Spotlight: Implementation of BIVA for Analyzing Disease Risk Factors in Patients with Low Body Cell Mass
Published on: July 14, 2023
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
Related Concept Videos
Longitudinal Research
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Longitudinal Studies
Accuracy and Precision
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...