Amperometric determination of nitrite using natural fibers as template for titanium dioxide nanotubes with
Balasubramanian Ranjani1, Jayaprakasham Kalaiyarasi1, Loganathan Pavithra2
1Department of Inorganic Chemistry, University of Madras, Guindy Campus, Chennai, 600025, India.
Abstract:
A sensing device was constructed for the amperometric determination of nitrite. It is based on the use of titanium dioxide (TiO2) nanotubes template with natural fibers and carrying hemin acting as the electron mediator. A glassy carbon electrode (GCE) was modified with the hemin/TNT nanocomposite. The electrochemical response to nitrite was characterized by impedance spectroscopy and cyclic voltammetry. An amperometric study, performed at a working potential of + 0.75 V (vs. Ag/AgCl), showed the sensor to enable determination of nitrite with a linear response in the 0.6 to 130 μM concentration range and with a 59 nM limit of detection. Corresponding studies by differential study voltammetry (Ep = 0.75 V) exhibited a linear range from 0.6 × 10-6 to 7.3 × 10-5 M with a limit of detection of 84 nM. The sensing device was applied to the determination of nitrite in spiked tap and lake water samples. Graphical abstract Natural fibers templated synthesis of TNT immobilized hemin as electron transfer mediator for quantitative detection of nitrite with detection limit of 59 nM and good electrochemical sensitivity and the method can be used for quantitative determination of nitrite in water samples.
Related Concept Videos
Ionic Bonding and Electron Transfer
DNA as a Genetic Template
DNA as a Genetic Template
Determining the pH of Salt Solutions
Carbon-dioxide Fixation
What is Natural Selection?