Microextraction of polycyclic aromatic hydrocarbons by using a stainless steel fiber coated with nanoparticles made from a porous aromatic framework
Related Experiment Video
Updated: Feb 12, 2026

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Wenchang Wang1, Zhi Li1, Wenjin Wang1
1Department of Chemistry, College of Science, Hebei Agricultural University, Baoding, 071001, China.
Abstract:
A porous aromatic framework of type PAF-6 was synthesized and explored as a coating onto a steel wire for using in solid-phase microextraction of polycyclic aromatic hydrocarbons (PAHs), phthalate plasticizers, and n-alkanes. The extraction temperature, extraction time, salt concentration, agitation speed, desorption temperature, and desorption time were optimized. This method for SPME resulted in the enrichment factors ranging from 122 to 1090 for PAHs (naphthalene, acenaphthene, fluorene, phenanthrene, anthracene, fluoranthene, pyrene), from 122 to 271 for plasticizers (diisobutyl phthalate, dibutyl phthalate, benzyl butyl phthalate, dicyclohexyl phthalate), and from 9 to 113 for n-alkanes (n-undecane, n-dodecane, n-tridecane, n-tetradecane, n-pentadecane, n-hexadecane, n-octadecane and n-eicosane). The good extraction of the PAHs is assumed to be due to their π-stacking interaction and hydrophobic effect. The PAF-6 coated fibers are durable and can be reused more than 100 times without significant loss of extraction performance. In combination with GC-MS detection, the method has limits of detection in the range from 0.8 to 4.2 ng L-1 in case of PAHs. The relative standard deviations for five replicate determinations of the PAHs by using one fiber are in the range from 5.2 to 8.5%. When using different fibers, they range from 7.1 to 9.6%. The recoveries of PAHs from water samples at a spiking level of 20 ng L-1 are in the range from 89.5 to 103.1%, with relative standard deviations ranging from 4.0 to 9.3%. Graphical abstract A porous aromatic framework of type PAF-6 was synthesized and used as a novel coating for the solid-phase microextraction of polycyclic aromatic hydrocarbons prior to their determination by gas chromatography with mass spectrometric detection.
Related Concept Videos
Aromatic Hydrocarbon Anions: Structural Overview
Due to the absence of continuous...
Aromatic Hydrocarbon Cations: Structural Overview
Removing one hydrogen from the intervening CH2 group...
Nucleophilic Aromatic Substitution of Aryldiazonium Salts: Aromatic SN1
In the Sandmeyer reaction, for example, the diazonio group is replaced by a chloro, bromo,...
Aromatic Compounds: Overview
In 1825, Faraday isolated...
Basicity of Aromatic Amines
Nomenclature of Aromatic Compounds with a Single Substituent

