Related Experiment Video
Updated: Feb 12, 2026

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
A ratiometric upconversion nanoprobe for fluorometric turn-on detection of sulfite and bisulfite
Shuailiang Wang1, Xiaozheng Cao1, Tang Gao1
1Xiangya School of Pharmaceutical Sciences, Central South University, Changsha, 410013, People's Republic of China.
Abstract:
A nanoprobe is described for the ratiometric fluorometric determination of sulfite ions. Upconversion nanoparticles (UCNPs) of the type β-NaYF4:Yb(III),Er(III),Tm(III) were covalently modified with the molecular probe HIAN which is a hydroxynaphthalimide fluorophore modified with a (cationic) indolinium moiety. Under excitation at 980 nm, the green emission of the UCNPs (peaking at 543 nm) is almost totally quenched, while the NIR emission (peaking at 802 nm) remains unaffected. In the presence of sulfite or bisulfite (hydrogen sulfite), the green fluorescence is restored and can be visually observed. A ratiometric method was worked out by measurement of the ratio of the green and NIR emissions. The analytical range extends from 10 to 250 μM, the limit of detection is 0.14 μM, and the assay can be performed within 40 s. Graphical abstract Based on the use of a molecular probe for sulfite and hydrogen sulfite, and by exploiting an inner filter effect (IFE), an assay for sulfite/hydrogen sulfite was developed by using upconversion nanoparticles (UCNPs). Addition reaction of sulfite/bisulfite with the material results in weakened IFE and enhanced green fluorescence of the UCNPs at excitation/emission wavelengths of 980/543 nm.
More Related Videos
07:54Surface-enhanced Resonance Raman Scattering Nanoprobe Ratiometry for Detecting Microscopic Ovarian Cancer via Folate Receptor Targeting
Published on: March 25, 2019
09:54Synthesis, Characterization, and Application of Superparamagnetic Iron Oxide Nanoprobes for Extrapulmonary Tuberculosis Detection
Published on: February 16, 2020
Related Concept Videos
Acids, Bases and Neutralization Reactions
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...