Introduction:
Cardiac ablation is an established treatment modality for the management of patients with cardiac arrhythmias. Current approaches to cardiac ablation employ thermal based energy to achieve lesions (damage) within the heart. There are many shortcomings and limitations of thermal based approaches. Electroporation (DC energy) is a non-thermal alternative approach to ablation that has shown significant promise in animal studies. Areas covered: An extensive review of the literature on the application of electroporation for ablation (both cardiac and collateral cardiac tissue) was undertaken. This review explores irreversible electroporation as a cardiac ablation modality. Specifically, it focuses and explains the biophysics of electroporation, the limitations of current thermal based approaches and examines the current data published on electroporation cardiac ablation. Expert commentary: Electroporation is a fast-growing novel ablation modality that has many advantages over current thermal based approaches. Current research in animal models shows its can be safely and efficaciously applied to the heart. Although further research is required, electroporation represents an appealing option for the ablation cardiac arrhythmias.
Related Concept Videos
Mechanism of Cardiac Arrhythmias
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
Reversible and Irreversible Processes
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...